{"id":600569,"date":"2024-11-05T22:06:25","date_gmt":"2024-11-05T22:06:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/iso-183262018\/"},"modified":"2024-11-05T22:06:25","modified_gmt":"2024-11-05T22:06:25","slug":"iso-183262018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/iso\/iso-183262018\/","title":{"rendered":"ISO 18326:2018"},"content":{"rendered":"
This document specifies the standard conditions for capacity and efficiency ratings of non-ducted portable air-cooled air conditioners having a single exhaust duct and non-ducted portable air-cooled heat pumps having a single exhaust duct. Such air conditioners and heat pumps may include an evaporatively cooled condenser cooled by air and the evaporation of:<\/p>\n
a) condensate collected from the evaporator;<\/p>\n
b) external supplementary water stored in a supplementary water tank; or<\/p>\n
c) both a) and b).<\/p>\n
This document also specifies the test methods for determining the capacity and efficiency ratings.<\/p>\n
This document applies to equipment that is factory-made, electrically driven and uses mechanical compression. This document is applicable to equipment utilizing one or more refrigeration systems.<\/p>\n
This document is not applicable to the rating and testing of the following:<\/p>\n
i) Water-source heat pumps or water-cooled air conditioners;<\/p>\n
ii) Multi-split-system air conditioners and air-to-air heat pumps (see ISO 15042:2017 for the testing of such equipment);<\/p>\n
iii) Individual assemblies not constituting a complete refrigeration system;<\/p>\n
iv) Equipment using the absorption refrigeration cycle;<\/p>\n
v) Ducted equipment (see ISO 13253:2017 for the testing of such equipment);<\/p>\n
vi) Evaporative coolers or any other cooling systems that are not of the vapour compression type;<\/p>\n
vii) Dehumidifiers;<\/p>\n
viii) Spot coolers.<\/p>\n","protected":false},"excerpt":{"rendered":"
Non-ducted portable air-cooled air conditioners and air-to-air heat pumps having a single exhaust duct \u2014 Testing and rating for performance<\/b><\/p>\n\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ISO<\/b><\/a><\/td>\n 2018-09<\/td>\n 54<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":600581,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[374,458,2634],"product_tag":[],"class_list":{"0":"post-600569","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-23-120","7":"product_cat-27-080","8":"product_cat-iso","10":"first","11":"instock","12":"sold-individually","13":"shipping-taxable","14":"purchasable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/600569","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/600581"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=600569"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=600569"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=600569"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}