{"id":457414,"date":"2024-10-20T09:51:03","date_gmt":"2024-10-20T09:51:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61169-702024\/"},"modified":"2024-10-26T18:18:19","modified_gmt":"2024-10-26T18:18:19","slug":"bs-en-iec-61169-702024","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61169-702024\/","title":{"rendered":"BS EN IEC 61169-70:2024"},"content":{"rendered":"
IEC 61169-70:2024, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) of HD-BNC series RF coaxial connectors together with the pro forma blank detail specification. HD-BNC series connectors with characteristic impedance of 75 \u03a9 are used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. The operating frequency limit is up to 18 GHz. It also prescribes mating face dimensions for general purpose connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series HD-BNC RF connectors. This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 4 Mating face and gauge information 4.1 Dimensions \u2013 General connectors \u2013 Grade 1 4.1.1 Connector with pin-centre contact <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Figures Figure 1 \u2013 Connector with pin-centre contact Figure 2 \u2013 Pin-centre contact <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4.1.2 Connector with socket-centre contact Tables Table 1 \u2013 Dimensions of connector with pin-centre contact <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Figure 3 \u2013 Connector with socket-centre contact Figure 4 \u2013 Socket- centre contact <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.1.3 Coupling nut details Table 2 \u2013 Dimensions of connector with socket-centre contact <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Figure 5 \u2013 Coupling nut details <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 4.2 Gauges 4.2.1 Gauge pin for socket-centre contact Figure 6 \u2013 Gauge pin for socket-centre contact Table 3 \u2013 Dimensions of coupling nut <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4.2.2 Gauge for outer contact of plug Table 4 \u2013 Dimensions of gauge pin for socket-centre contact <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5 Quality assessment procedure 5.1 General Figure 7 \u2013 Gauge for outer contact of plug Table 5 \u2013 Dimensions of outer contact gauge <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.2 Rating and characteristics (see IEC 61169-1:2013, Clause 5) Table 6 \u2013 Rating and characteristics <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.3 Test schedule and inspection requirements 5.3.1 Acceptance tests 5.3.2 Periodic tests Table 7 \u2013 Acceptance tests Table 8 \u2013 Periodic tests <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.4 Procedures 5.4.1 Quality conformance inspection <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 5.4.2 Quality conformance and its maintenance 6 Instructions for preparation of detail specifications (DS) 6.1 General 6.2 Identification of the component 6.3 Performance 6.4 Marking, ordering information and related matters <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 6.5 Selection of tests, test conditions and severities 6.6 Blank detail specification pro forma for series HD-BNC connectors <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Radio-frequency connectors – Sectional specification for series HD-BNC radio-frequency coaxial connectors. Characteristic Impedance 75 \u03a9<\/b><\/p>\n |