{"id":440910,"date":"2024-10-20T08:18:16","date_gmt":"2024-10-20T08:18:16","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-tr-127672023-tc\/"},"modified":"2024-10-26T15:30:22","modified_gmt":"2024-10-26T15:30:22","slug":"bsi-pd-iso-tr-127672023-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-tr-127672023-tc\/","title":{"rendered":"BSI PD ISO\/TR 12767:2023 – TC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
70<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | 4 Symbols <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | 5 Effect of errors on flowrate calculations 5.1 General 5.2 Quantifiable effects 6 Effects of deviations in construction 6.1 Orifice-plate edge sharpness <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | 6.2 Thickness of orifice edge <\/td>\n<\/tr>\n | ||||||
81<\/td>\n | 6.3 Condition of upstream and downstream faces of orifice plate <\/td>\n<\/tr>\n | ||||||
82<\/td>\n | 6.4 Position of pressure tappings for an orifice 6.4.1 General 6.4.2 Calculation of discharge coefficient 6.4.3 Estimation of additional uncertainty 6.4.4 Example <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | 6.5 Condition of pressure tappings 7 Effects of pipeline near the meter 7.1 Pipe diameter 7.2 Steps and taper sections <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | 7.3 Diameter of carrier ring <\/td>\n<\/tr>\n | ||||||
87<\/td>\n | 7.4 Undersize joint rings 7.5 Protruding welds 7.6 Eccentricity <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | 8 Effects of pipe layout 8.1 General <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | 8.2 Discharge coefficient compensation 8.2.1 Corrections <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | 8.2.2 Additional uncertainty <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | 8.3 Pressure tappings 8.4 Devices for improving flow conditions 9 Operational deviations 9.1 General <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | 9.2 Deformation of an orifice plate 9.2.1 General 9.2.2 Elastic deformation 9.2.3 Plastic deformation <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | 9.3 Deposition on the upstream face of an orifice plate <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | 9.4 Deposition in the meter tube <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | 9.5 Orifice-plate edge sharpness 9.5.1 Deterioration 9.5.2 Plate reversal <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | 9.6 Deposition and increase of surface roughness in Venturi tubes 9.6.1 General 9.6.2 Deposition 9.6.3 Surface roughness <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | 10 Pipe roughness 10.1 General <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | 10.2 Upstream pipe <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | 10.3 Downstream pipe 10.4 Reduction of roughness effects 10.5 Maintenance <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Measurement of fluid flow by means of pressure differential devices. Guidelines on the effect of departure from the specifications and operating conditions given in ISO 5167<\/b><\/p>\n |