{"id":276320,"date":"2024-10-19T18:35:50","date_gmt":"2024-10-19T18:35:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-72112012a12020\/"},"modified":"2024-10-25T15:02:17","modified_gmt":"2024-10-25T15:02:17","slug":"bs-72112012a12020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-72112012a12020\/","title":{"rendered":"BS 7211:2012+A1:2020"},"content":{"rendered":"
This British Standard specifies requirements and test methods for the construction and performance of cables that:<\/p>\n
have a thermosetting insulation of rated voltage up to and including 450\/750 V;<\/p>\n<\/li>\n
emit limited amounts of smoke (see 16.6<\/b>) and corrosive gases when subjected to relevant tests compared with corresponding PVC cables conforming to BS 6004;<\/p>\n<\/li>\n are intended for electric power and lighting.<\/p>\n<\/li>\n<\/ol>\n The types of cable included in this British Standard are:<\/p>\n thermosetting insulated and thermoplastic low smoke halogen free sheathed cable 450\/750 V single core 6181B (see Table 3);<\/p>\n<\/li>\n thermosetting insulated and thermoplastic low smoke halogen free sheathed circular cables 450\/750 V, 2-core 6182B, 3-core 6183B, 4-core 6184B and 5-core 6185B (see Table 4);<\/p>\n<\/li>\n thermosetting insulated and thermoplastic low smoke halogen free sheathed cables 300\/500 V single-core 6241B, flat twin 6242B, flat 3-core 6243B with circuit protective conductor (see Table 5).<\/p>\n<\/li>\n<\/ul>\n The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90 \u00b0C and for a maximum short-circuit conductor temperature of 250 \u00b0C (for a maximum period of 5 s).<\/p>\n NOTE 1 Limitation on the temperature of the cables may be imposed in situations where they could be touched, or where they could touch other materials.<\/p>\n<\/blockquote>\n NOTE 2 In installations that include wiring accessories, junction boxes and consumer units etc., the performance of these accessories should be taken into account in deciding the maximum operating temperature of the cable.<\/p>\n<\/blockquote>\n NOTE 3 Annex A provides a guide to the cross-referencing of the traditional United Kingdom Cable Codes (formerly known as the CMA codes) and harmonized CENELEC codes. Furthermore, Annex B gives information on the traditional UK cables transferred to BS EN 50525.<\/p>\n<\/blockquote>\n NOTE 4 Annex C gives guidance on the use of the cables specified in this British Standard.<\/p>\n<\/blockquote>\n NOTE 5 Annex D gives the compatibility test method.<\/p>\n<\/blockquote>\n NOTE 6 Annex E gives the voltage withstand test.<\/p>\n<\/blockquote>\n NOTE 7 Annex F gives notes on type tests.<\/p>\n<\/blockquote>\n NOTE 8 In this British Standard, corrosive (and acid) gases are defined as those that are determined as HCl.<\/p>\n<\/blockquote>\n Electric cables. Thermosetting insulated and thermoplastic sheathed cables for voltages up to and including 450\/750 V for electric power and lighting and having low emission of smoke and corrosive gases when affected by fire<\/b><\/p>\n\n
\n
\n
\n
\n
\n
\n
\n
\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 4<\/td>\n Foreword <\/td>\n<\/tr>\n \n 7<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 8<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 9<\/td>\n 4 Rated voltage
Table 1 \u2014 Maximum permitted voltages against rated voltage of cable
5 Construction <\/td>\n<\/tr>\n\n 10<\/td>\n 6 Conductors
7 Insulation system <\/td>\n<\/tr>\n\n 11<\/td>\n 8 Identification of cores
9 Multi-core circular cables <\/td>\n<\/tr>\n\n 12<\/td>\n 10 Optional extruded inner covering
11 Sheath <\/td>\n<\/tr>\n\n 13<\/td>\n 12 Cable marking and additional information <\/td>\n<\/tr>\n \n 14<\/td>\n Figure 1 \u2014 An example of the marking as used on the outer sheath of the cable <\/td>\n<\/tr>\n \n 15<\/td>\n 13 Schedule of tests
Table 2 \u2014 Schedule of tests <\/td>\n<\/tr>\n\n 16<\/td>\n 14 Test conditions
15 Routine tests <\/td>\n<\/tr>\n\n 17<\/td>\n 16 Sample tests <\/td>\n<\/tr>\n \n 18<\/td>\n 17 Type tests <\/td>\n<\/tr>\n \n 20<\/td>\n Table 3 \u2014 Thermosetting insulated, single-core, sheathed cables 6181B, 450\/750 V <\/td>\n<\/tr>\n \n 21<\/td>\n Table 4 \u2014 Thermosetting insulated, circular 2-core 6182B, 3-core 6183B, 4-core 6184B, 5-core 6185B sheathed cables, 450\/750 V <\/td>\n<\/tr>\n \n 23<\/td>\n Table 5 \u2014 Thermosetting insulated, single core 6241B, flat twin 6242B and flat 3-core 6243B sheathed cables with circuit protective conductor (CPC) 300\/500 V <\/td>\n<\/tr>\n \n 24<\/td>\n Annex A (informative)\u2002 Coding cross references
Table A.1 \u2014 UK and harmonized CENELEC coding cross references
Annex B (informative)\u2002 Traditional UK cables transferred to BS EN 50525
Table B.1 \u2014 Halogen free, low smoke, conduit cable 450\/750 V: formerly in BS 7211 <\/td>\n<\/tr>\n\n 25<\/td>\n Table B.2 \u2014 Halogen free, low smoke, flexible conduit cable 450\/750 V: formerly in BS 7211 <\/td>\n<\/tr>\n \n 26<\/td>\n Table B.3 \u2014 Halogen free, low smoke, conduit cable 300\/500 V: formerly in BS 7211
Table B.4 \u2014 Halogen free low smoke flexible conduit cable 300\/500 V: formerly in BS 7211
Annex C (informative)\u2002 Guide to use <\/td>\n<\/tr>\n\n 27<\/td>\n Table C.1 \u2014 Constructional details, methods of installation and temperature for Table 3 to Table 5 <\/td>\n<\/tr>\n \n 28<\/td>\n Table C.2 \u2014 Guide to use
Annex D (normative)\u2002 Compatibility test <\/td>\n<\/tr>\n\n 29<\/td>\n Table D.1 \u2014 Compatibility requirements
Annex E (normative)\u2002 Method of test for voltage withstand <\/td>\n<\/tr>\n\n 30<\/td>\n Annex F (informative)\u2002 Notes on type tests <\/td>\n<\/tr>\n \n 32<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2020<\/td>\n 34<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":276326,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[493,2641],"product_tag":[],"class_list":{"0":"post-276320","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-060-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/276320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/276326"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=276320"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=276320"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=276320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}