{"id":239014,"date":"2024-10-19T15:37:36","date_gmt":"2024-10-19T15:37:36","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-dd-iec-pas-62282-6-1502011\/"},"modified":"2024-10-25T10:19:18","modified_gmt":"2024-10-25T10:19:18","slug":"bsi-dd-iec-pas-62282-6-1502011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-dd-iec-pas-62282-6-1502011\/","title":{"rendered":"BSI DD IEC\/PAS 62282-6-150:2011"},"content":{"rendered":"

IEC\/PAS 62282-6-150:2011(E) covers micro fuel cell power systems using hydrogen produced from the reaction of an aqueous solution with solid UN Division 4.3 (water-reactive) compounds in indirect PEM fuel cell systems that are wearable or easily carried by hand, providing d.c. outputs that do not exceed 60 V d.c. and power outputs that do not exceed 240 VA.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nCONTENTS
\n <\/td>\n<\/tr>\n
9<\/td>\nFOREWORD <\/td>\n<\/tr>\n
11<\/td>\n1 Scope
1.1 General
1.2 Fuels and technologies covered <\/td>\n<\/tr>\n
12<\/td>\nFigures
\n
Figure 1.1 \u2013 Micro fuel cell power system block diagram for UN Division 4.3(water reactive) compound fuel in indirect PEM fuel cell system \u2013 Fuel management system in micro fuel cell power unit <\/td>\n<\/tr>\n
13<\/td>\n1.3 Equivalent level of safety
Figure 1.2 \u2013 Micro fuel cell power system block diagram for UN Division 4.3(water reactive) compound fuel in indirect PEM fuel cell system \u2013 Fuel management system in fuel cartridge <\/td>\n<\/tr>\n
14<\/td>\n2 Normative references <\/td>\n<\/tr>\n
15<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
20<\/td>\n4 Materials and construction of micro fuel cell power systems, micro fuel cell power units and fuel cartridges
4.1 General
4.2 FMEA\/hazard analysis <\/td>\n<\/tr>\n
21<\/td>\n4.3 General materials
4.4 Selection of materials <\/td>\n<\/tr>\n
22<\/td>\n4.5 General construction
4.6 Fuel valves
4.7 Materials and construction \u2013 System <\/td>\n<\/tr>\n
23<\/td>\n4.8 Ignition sources
4.9 Enclosures and acceptance strategies <\/td>\n<\/tr>\n
25<\/td>\nTables
\n
Table 1 \u2013 Summary of material flammability requirements <\/td>\n<\/tr>\n
27<\/td>\n4.10 Protection against fire, explosion, corrosivity and toxicity hazard <\/td>\n<\/tr>\n
28<\/td>\n4.11 Protection against electrical hazards
4.12 Fuel supply construction <\/td>\n<\/tr>\n
29<\/td>\n4.13 Protection against mechanical hazards <\/td>\n<\/tr>\n
30<\/td>\nTable 2 \u2013 Temperature limits <\/td>\n<\/tr>\n
31<\/td>\n4.14 Construction of electric device components
Table 3 \u2013 Limits for inherently limited power sources
Table 4 \u2013 Limits for power sources not inherently limited (over-current protection required) <\/td>\n<\/tr>\n
33<\/td>\n5 Abnormal operating and fault conditions testing and requirements
5.1 General <\/td>\n<\/tr>\n
34<\/td>\n5.2 Compliance testing
5.3 Passing criteria <\/td>\n<\/tr>\n
35<\/td>\n5.4 Simulated faults and abnormal conditions for limited power and SELV circuits
5.5 Abnormal operation \u2013 electromechanical components
5.6 Abnormal operation of micro fuel cell power systems or units with integrated batteries <\/td>\n<\/tr>\n
36<\/td>\n5.7 Abnormal operation \u2013 Simulation of faults based on hazard analysis
6 Instructions and warnings for micro fuel cell power systems, micro fuel cell power units and fuel cartridges
6.1 General
6.2 Minimum markings required on the fuel cartridge <\/td>\n<\/tr>\n
37<\/td>\n6.3 Minimum markings required on the micro fuel cell power system or micro fuel cell power unit
6.4 Additional information required either on the fuel cartridge or on accompanying written information or on the micro fuel cell power system or micro fuel cell power unit <\/td>\n<\/tr>\n
38<\/td>\n6.5 Technical documentation
7 Type tests for micro fuel cell power systems, micro fuel cell power units and fuel cartridges
7.1 General <\/td>\n<\/tr>\n
39<\/td>\nTable 5 \u2013 List of type tests <\/td>\n<\/tr>\n
40<\/td>\n7.2 Leakage, hydrogen leakage, and hydrogen gas loss, and hydrogen emission measurement and the measuring procedures
Table 6 \u2013 Laboratory standard conditions <\/td>\n<\/tr>\n
42<\/td>\nFigure 2 \u2013 Fuel cartridge leakage test flow chart for pressure differential,vibration, drop, and compressive loading tests <\/td>\n<\/tr>\n
43<\/td>\nFigure 3 \u2013 Fuel cartridge leakage test flow chart for temperature cycling testand high temperature exposure test <\/td>\n<\/tr>\n
44<\/td>\nFigure 4 \u2013 Micro fuel cell power system or micro fuel cell power unit leakage and hydrogen gas loss test flow chart for vibration, temperature cycling, drop and compressive loading tests <\/td>\n<\/tr>\n
45<\/td>\nFigure 5 \u2013 Micro fuel cell power system or micro fuel cell power unit leakage and hydrogen gas loss test flow chart for external short-circuit test <\/td>\n<\/tr>\n
46<\/td>\nFigure 6 \u2013 Micro fuel cell power system or micro fuel cell power unit leakage and hydrogen gas loss test flow chart for 68 kPa low external pressure test <\/td>\n<\/tr>\n
47<\/td>\nFigure 7 \u2013 Micro fuel cell power system or micro fuel cell power unit leakage and hydrogen gas loss test flow chart for 11,6 kPa low external pressure test
\n <\/td>\n<\/tr>\n
48<\/td>\n7.3 Type tests <\/td>\n<\/tr>\n
54<\/td>\nFigure 8 \u2013 Temperature cycling <\/td>\n<\/tr>\n
62<\/td>\nFigure 9 \u2013 Fuel cartridge leakage and hydrogen gas loss test flow chartfor long-term storage test. <\/td>\n<\/tr>\n
69<\/td>\nFigure 10 \u2013 Operational emission rate testing apparatus <\/td>\n<\/tr>\n
70<\/td>\nFigure 11 \u2013 Operational emission concentration testing apparatus <\/td>\n<\/tr>\n
76<\/td>\nTable 7 \u2013 Emission limits <\/td>\n<\/tr>\n
77<\/td>\nFigure 12 \u2013 Hydrogen emission test procedure for operating micro fuel cell power system <\/td>\n<\/tr>\n
78<\/td>\nFigure 13 \u2013 Fuel cartridge leakage test flow chart for low external pressure test <\/td>\n<\/tr>\n
81<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Fuel cell technologies – Micro fuel cell power systems. Safety. Water reactive (UN Division 4.3) compounds in indirect PEM fuel cells<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2011<\/td>\n86<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":239022,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-239014","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/239014","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/239022"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=239014"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=239014"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=239014"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}