{"id":238892,"date":"2024-10-19T15:37:00","date_gmt":"2024-10-19T15:37:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-62246-12011\/"},"modified":"2024-10-25T10:18:33","modified_gmt":"2024-10-25T10:18:33","slug":"bs-en-62246-12011","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-62246-12011\/","title":{"rendered":"BS EN 62246-1:2011"},"content":{"rendered":"
This part of IEC 62246 series, which is a generic specification applies to all types of reed switches including magnetically biased reed switches of assessed quality for use in general and industrial applications.<\/p>\n
\nNOTE 1 Mercury wetted reed switches are not covered by this standard due to their possible environmental impact.<\/p>\n<\/blockquote>\n
It lists the tests and measurement procedures which may be selected for use in detail specifications for such reed switches. This standard also specifies the quality assessment procedures to be followed.<\/p>\n
This standard applies to reed switches which are operated by an applied magnetic field; it is not restricted to any particular type of contact load.<\/p>\n
\nNOTE 2 For elementary relays with reed switches, this standard is recommended to be used together with the standards IEC 61810-1 and IEC 61811-1 as applicable.<\/p>\n
NOTE 3 The applications of reed switches can be covered by specific product standards and the use of the IEC 62246 series does not guarantee compliance with those standards.<\/p>\n
NOTE 4 Where any discrepancies occur for any reasons, documents rank in the following order of authority:<\/p>\n<\/blockquote>\n
\n
- \n
the detail specification,<\/p>\n<\/li>\n
- \n
the sectional specification,<\/p>\n<\/li>\n
- \n
the generic specification,<\/p>\n<\/li>\n
- \n
any other international documents (for example, of the IEC) to which reference is made.<\/p>\n<\/li>\n<\/ol>\n
The same order of precedence applies to equivalent national documents.<\/p>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 8<\/td>\n English
\n
CONTENTS <\/td>\n<\/tr>\n\n 13<\/td>\n 1 Scope
2 Normative references <\/td>\n<\/tr>\n\n 14<\/td>\n 3 Terms and definitions
3.1 Terms and definitions of reed switch types <\/td>\n<\/tr>\n\n 15<\/td>\n 3.2 Terms and definitions of operating values <\/td>\n<\/tr>\n \n 16<\/td>\n Figures
\n
Figure\u00a01 \u2013 Functional characteristics <\/td>\n<\/tr>\n\n 17<\/td>\n 3.3 Terms and definitions related to operating times (see Figure\u00a02) <\/td>\n<\/tr>\n \n 18<\/td>\n Figure\u00a02 \u2013 Time definitions <\/td>\n<\/tr>\n \n 20<\/td>\n 3.4 Terms and definitions related to contacts <\/td>\n<\/tr>\n \n 22<\/td>\n 4 Rated values
4.1 General <\/td>\n<\/tr>\n\n 23<\/td>\n 4.2 Frequency of operation
4.3 Duty factor
4.4 Open-circuit voltage across contacts
4.5 Current rating
4.6 Load ratings
4.7 Number of operations
4.8 Climatic category <\/td>\n<\/tr>\n\n 24<\/td>\n 4.9 Environmental severities
4.10 Surge voltage <\/td>\n<\/tr>\n\n 25<\/td>\n 4.11 Classification
4.12 Contact reliability
5 Marking
Tables
\n
Table 1 \u2013 Classification <\/td>\n<\/tr>\n\n 26<\/td>\n 6 Quality assessment procedures
6.1 General
6.2 Supplier\u2019s declaration of conformity
6.3 Second-party conformity assessment
6.4 Third-party certification
6.5 IECEE scheme
6.6 IECQ system <\/td>\n<\/tr>\n\n 28<\/td>\n 7 Test and measurement procedures
7.1 General
7.2 Alternative procedures <\/td>\n<\/tr>\n\n 29<\/td>\n 7.3 Standard conditions for testing
7.4 Visual inspection and check of dimensions <\/td>\n<\/tr>\n\n 30<\/td>\n 7.5 Functional tests <\/td>\n<\/tr>\n \n 31<\/td>\n 7.6 Remanence test (see Figure\u00a03) <\/td>\n<\/tr>\n \n 32<\/td>\n 7.7 Contact circuit resistance
Figure\u00a03 \u2013 Remanence test sequence <\/td>\n<\/tr>\n\n 33<\/td>\n Figure\u00a04 \u2013 Sequence of contact circuit resistance measurement <\/td>\n<\/tr>\n \n 34<\/td>\n 7.8 Dielectric test
7.9 Insulation resistance <\/td>\n<\/tr>\n\n 35<\/td>\n 7.10 Operating times (see Figures\u00a02, 5 and 6) <\/td>\n<\/tr>\n \n 37<\/td>\n Figure\u00a05 \u2013 Test circuit for the measurement of release and bounce timeof a make switch <\/td>\n<\/tr>\n \n 38<\/td>\n 7.11 Contact sticking
Figure\u00a06 \u2013 Test circuit for the measurement of time parametersof a change-over switch <\/td>\n<\/tr>\n\n 41<\/td>\n 7.12 Robustness of terminals
7.13 Soldering (solderability and resistance to soldering heat) <\/td>\n<\/tr>\n\n 42<\/td>\n 7.14 Climatic sequence <\/td>\n<\/tr>\n \n 43<\/td>\n 7.15 Damp heat, steady state
7.16 Rapid change of temperature
7.17 Salt mist <\/td>\n<\/tr>\n\n 44<\/td>\n 7.18 Vibration <\/td>\n<\/tr>\n \n 45<\/td>\n 7.19 Shock <\/td>\n<\/tr>\n \n 46<\/td>\n 7.20 Acceleration test \u2013 Functional test only
7.21 Sealing <\/td>\n<\/tr>\n\n 47<\/td>\n 7.22 Electrical endurance <\/td>\n<\/tr>\n \n 50<\/td>\n Table\u00a02 \u2013 Resistive loads <\/td>\n<\/tr>\n \n 51<\/td>\n Table\u00a03 \u2013 Loads
Table\u00a04 \u2013 Cables <\/td>\n<\/tr>\n\n 52<\/td>\n Table 5 \u2013 Making and breaking capacity for electrical endurance tests <\/td>\n<\/tr>\n \n 54<\/td>\n 7.23 Mechanical endurance <\/td>\n<\/tr>\n \n 55<\/td>\n 7.24 Maximum cycling frequency <\/td>\n<\/tr>\n \n 56<\/td>\n 7.25 Surge withstand test <\/td>\n<\/tr>\n \n 57<\/td>\n 7.26 Making and breaking capacities <\/td>\n<\/tr>\n \n 59<\/td>\n Table 6 \u2013 Verification of making and breaking capacity under normal conditions <\/td>\n<\/tr>\n \n 60<\/td>\n 7.27 Conditional short-circuit current test
Table 7 \u2013 Verification of making and breaking capacity under abnormal conditions <\/td>\n<\/tr>\n\n 61<\/td>\n 7.28 Contact reliability test <\/td>\n<\/tr>\n \n 63<\/td>\n 7.29 Temperature rise <\/td>\n<\/tr>\n \n 64<\/td>\n 7.30 Making current capacity test <\/td>\n<\/tr>\n \n 65<\/td>\n 7.31 Breaking current capacity test <\/td>\n<\/tr>\n \n 67<\/td>\n Annex A (normative)
\nStandard test coils for reed switches
Figure A.1 \u2013 Configuration of test coils <\/td>\n<\/tr>\n\n 68<\/td>\n Table A.1 \u2013 List of standard test coils <\/td>\n<\/tr>\n \n 69<\/td>\n Annex B (normative)
\nTest systems
Figure B.1 \u2013 Test system 1
Figure B.2 \u2013 Test system 2 <\/td>\n<\/tr>\n\n 71<\/td>\n Annex C (informative)
\nElectrical endurance test circuit
Figure C.1 \u2013 Generalized endurance test circuit <\/td>\n<\/tr>\n\n 72<\/td>\n Figure C.2 \u2013 Functional block diagram <\/td>\n<\/tr>\n \n 73<\/td>\n Annex D (informative)
\nInrush current loads
Figure D.1 \u2013 Circuit for filament lamp load <\/td>\n<\/tr>\n\n 74<\/td>\n Figure D.2 \u2013 Example for capacitive load test <\/td>\n<\/tr>\n \n 75<\/td>\n Annex E (informative)
\nConditional short-circuit current test circuit
Figure E.1 \u2013 Conditional short-circuit current test circuit <\/td>\n<\/tr>\n\n 76<\/td>\n Annex F (informative)
\nElectrical ratings based on classification
Table F.1 \u2013 Examples of contact rating designation based on classification <\/td>\n<\/tr>\n\n 77<\/td>\n Annex G (informative)
\nExample of test arrangement for contact reliability test
Figure G.1 \u2013 Contact reliability test circuit <\/td>\n<\/tr>\n\n 78<\/td>\n Annex H (informative)
\nExample of test arrangement for making current capacity test
Figure H.1 \u2013 Making current capacity test circuit
Figure H.2 \u2013 Making current capacity test sequence <\/td>\n<\/tr>\n\n 79<\/td>\n Annex I (informative)
\nExample of test arrangement for breaking current capacity test
Figure I.1 \u2013 Breaking current capacity test circuit
Figure I.2 \u2013 Breaking current capacity test sequence <\/td>\n<\/tr>\n\n 80<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Reed switches – Generic specification<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2011<\/td>\n 82<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":238898,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[512,2641],"product_tag":[],"class_list":{"0":"post-238892","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-120-70","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/238892","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/238898"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=238892"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=238892"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=238892"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}