{"id":222525,"date":"2024-10-19T14:26:50","date_gmt":"2024-10-19T14:26:50","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-12326-12014\/"},"modified":"2024-10-25T08:03:05","modified_gmt":"2024-10-25T08:03:05","slug":"bs-en-12326-12014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-12326-12014\/","title":{"rendered":"BS EN 12326-1:2014"},"content":{"rendered":"

This European Standard specifies requirements for slate and carbonate slate for discontinuous roofing and external cladding, as defined in 3.1<\/span>, and 3.2<\/span>, used for assembly into discontinuous roofing and external cladding.<\/p>\n

For the purposes of this European Standard, slates and carbonate slates have been classified.<\/p>\n

This European Standard does not apply to products for roofing or external cladding made from the following:<\/p>\n

    \n
  1. \n

    stone other than those defined in 3.1<\/span> and 3.2<\/span>;<\/p>\n<\/li>\n

  2. \n

    concrete;<\/p>\n<\/li>\n

  3. \n

    polymeric materials;<\/p>\n<\/li>\n

  4. \n

    fibre reinforced cement;<\/p>\n<\/li>\n

  5. \n

    metal;<\/p>\n<\/li>\n

  6. \n

    clay.<\/p>\n<\/li>\n<\/ol>\n

    This European Standard is not applicable to roofing and cladding slates used internally.<\/p>\n

    This European Standard is not applicable to bonded cladding (cladding fixed with adhesives) and cladding fixed with dowels and cramps.<\/p>\n

    \n
    \n NOTE 1\n <\/div>\n

    Requirements for internal wall lining slate are specified in EN 1469<\/span> <\/span>.<\/p>\n<\/div>\n

    This document does not include requirements for appearance.<\/p>\n

    \n
    \n NOTE 2\n <\/div>\n

    Some general guidance for appearance is given in Annex A<\/span>.<\/p>\n<\/div>\n

    This European Standard does not include installation rules for slates.<\/p>\n

    \n
    \n NOTE 3\n <\/div>\n

    References to national recommendations on methods of construction for slate roofs are given in Annex C<\/span>.<\/p>\n<\/div>\n

    \n
    \n NOTE 4\n <\/div>\n

    Where the term \u201cslate\u201d is used in this document it means slate and carbonate slate unless otherwise indicated.<\/p>\n<\/div>\n

    PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
    PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
    6<\/td>\nForeword <\/td>\n<\/tr>\n
    7<\/td>\nIntroduction <\/td>\n<\/tr>\n
    8<\/td>\n1 Scope
    2 Normative references <\/td>\n<\/tr>\n
    9<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
    10<\/td>\n4 Symbols and abbreviations <\/td>\n<\/tr>\n
    11<\/td>\n5 Requirements
    5.1 Origin and petrography
    5.2 Thickness
    5.2.1 General
    5.2.2 Nominal thickness
    5.2.3 Individual thickness <\/td>\n<\/tr>\n
    13<\/td>\nFigure 1 \u2014 Flow chart for the control of the nominal and individual thickness of slates <\/td>\n<\/tr>\n
    14<\/td>\nTable 1 \u2014 Minimum individual thickness of slates in relation to the apparent calcium carbonate content and the sulfur dioxide exposure code
    5.3 Characteristic modulus of rupture
    5.4 Grain
    5.5 Water absorption <\/td>\n<\/tr>\n
    15<\/td>\nTable 2 \u2014 Water absorption requirements
    5.6 Freeze\u2013thaw resistance (for slates with water absorption > 0,6)
    5.7 Thermal cycle resistance
    Table 3 \u2014 Thermal cycle requirements
    5.8 Apparent calcium carbonate content
    5.9 Sulfur dioxide exposure test <\/td>\n<\/tr>\n
    16<\/td>\nFigure 2 \u2014 Coding for sulfur dioxide exposure test
    5.10 Non-carbonate carbon content
    5.11 Defects
    5.12 Other dimensions
    5.12.1 General
    5.12.2 Deviation of length and width <\/td>\n<\/tr>\n
    17<\/td>\n5.12.3 Deviation from edge straightness
    5.12.4 Deviation from rectangularity
    Figure 3 \u2014 Deviations from straightness of edges and rectangularity
    5.12.5 Deviation from flatness <\/td>\n<\/tr>\n
    18<\/td>\nTable 4 \u2014 Maximum deviation from flatness for rectangular slates
    5.12.6 Format of random slates and special shaped slates
    5.13 Fire
    5.13.1 External fire performance
    5.13.2 Reaction to fire performance <\/td>\n<\/tr>\n
    19<\/td>\n5.14 Release of dangerous substances
    6 Assessment and verification of constancy of performance – AVCP
    6.1 General <\/td>\n<\/tr>\n
    20<\/td>\n6.2 Number of slates required for type tests and factory production control
    Table 5 \u2014 Testing requirements and number of slates required for type testing and factory production control
    6.3 Testing frequency <\/td>\n<\/tr>\n
    21<\/td>\nTable 6 \u2014 Characteristics, test frequencies and compliance criteria <\/td>\n<\/tr>\n
    22<\/td>\n6.4 Type testing
    6.4.1 General
    6.4.2 Test Reports
    6.5 Factory production control (FPC)
    6.5.1 General
    6.5.2 Product related requirements
    6.5.2.1 Verification of origin and petrographic examination
    6.5.2.2 Verification of dimensions and measurement of dimensional variation <\/td>\n<\/tr>\n
    23<\/td>\n6.5.2.3 Rock properties
    6.5.3 Procedures in case of nonconformity and\/or complaint
    6.5.3.1 General
    6.5.3.2 Sampling lots <\/td>\n<\/tr>\n
    24<\/td>\n6.5.3.3 Sampling
    6.5.3.4 Acceptance or re-designation of a lot
    Figure 4 \u2014 Decision tree for nonconformity and\/or complaint procedures <\/td>\n<\/tr>\n
    25<\/td>\n7 Marking, labelling and packaging <\/td>\n<\/tr>\n
    26<\/td>\nAnnex A (informative) Appearance of slates
    A.1 Colour
    A.2 Marks <\/td>\n<\/tr>\n
    27<\/td>\nAnnex B (informative) Guidance for the calculation of the basic individual thickness of slates
    B.1 Calculation of the basic individual thickness of slates <\/td>\n<\/tr>\n
    28<\/td>\nB.2 National X factors
    Table B.1 \u2014 National X factors
    B.3 Example calculations for minimum thickness of slates
    B.3.1 Nominal thickness
    B.3.2 Examples for the calculation of nominal thickness <\/td>\n<\/tr>\n
    32<\/td>\nAnnex C (informative) General guidance on the installation of slates
    Table C.1 \u2014 National recommendations on methods of construction for slate roofs <\/td>\n<\/tr>\n
    33<\/td>\nAnnex D (informative) Format for the accompanying commercial document <\/td>\n<\/tr>\n
    34<\/td>\nTable D.1 \u2014 Format for the first part of the accompanying commercial document <\/td>\n<\/tr>\n
    35<\/td>\nTable D.2 \u2014 Format for the accompanying commercial document <\/td>\n<\/tr>\n
    37<\/td>\nAnnex E (informative) Method to estimate the nominal thickness of packed slates epc3F )
    E.1 Principle
    E.2 Apparatus
    E.3 Preparation of test pieces
    E.4 Procedure
    E.5 Expression of results
    E.6 Test report <\/td>\n<\/tr>\n
    38<\/td>\nAnnex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation
    ZA.1 Scope and relevant characteristics
    Table ZA.1.1 \u2014 Relevant clauses for slate and carbonate slate and intended use \u2014 Discontinuous roofing <\/td>\n<\/tr>\n
    40<\/td>\nTable ZA.1.2 \u2014 Relevant clauses for slate and carbonate slate and intended use \u2013 external cladding <\/td>\n<\/tr>\n
    41<\/td>\nZA.2 Procedure for AVCP of the slate and carbonate slate for discontinuous roofing and external cladding
    ZA.2.1 Systems of AVCP <\/td>\n<\/tr>\n
    42<\/td>\nTable ZA.2 \u2014 Systems of AVCP <\/td>\n<\/tr>\n
    43<\/td>\nTable ZA.3.1\u2014 Assignment of AVCP tasks for the slate and carbonate slate for discontinuous roofing and external cladding under System 3
    Table ZA.3.2 \u2014 Assignment of AVCP tasks for the slate and carbonate slate for discontinuous roofing and external cladding under System 4
    ZA.2.2 Declaration of performance (DoP)
    ZA.2.2.1 General <\/td>\n<\/tr>\n
    44<\/td>\nZA.2.2.2 Content <\/td>\n<\/tr>\n
    45<\/td>\nZA.2.2.3 Example of DoP <\/td>\n<\/tr>\n
    47<\/td>\nZA.3 CE marking marking and labelling <\/td>\n<\/tr>\n
    48<\/td>\nFigure ZA.1 \u2014 Example CE marking information of products under AVCP System 4 <\/td>\n<\/tr>\n
    49<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

    Slate and stone for discontinuous roofing and external cladding – Specifications for slate and carbonate slate<\/b><\/p>\n\n\n\n\n
    Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
    BSI<\/b><\/a><\/td>\n2014<\/td>\n52<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":222527,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1255,2641],"product_tag":[],"class_list":{"0":"post-222525","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-100-15","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/222525","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/222527"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=222525"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=222525"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=222525"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}