{"id":198004,"date":"2024-10-19T12:36:23","date_gmt":"2024-10-19T12:36:23","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/aami-tir60-2014-ra-2019\/"},"modified":"2024-10-25T05:09:38","modified_gmt":"2024-10-25T05:09:38","slug":"aami-tir60-2014-ra-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/aami\/aami-tir60-2014-ra-2019\/","title":{"rendered":"AAMI TIR60 2014 RA 2019"},"content":{"rendered":"

This technical information report (TIR) provides the details of how to correctly build, calibrate, and use the CMR test circuit specified in ECG performance standards. It also preserves the history, rationale, and performance requirements of the test method, as included in ANSI\/AAMI EC13:2002, Cardiac monitors, heart rate meters, and alarms, which was revised by the adoption and finalization of ANSI\/AAMI\/IEC 60601-2-27:2011, Medical electrical equipment – Part 2-27: Particular requirements for the basic safety and essential performance of electrocardiographic monitoring equipment.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nAAMI TIR60:2014\/(R)2019, Common mode rejection in ECG monitoring <\/td>\n<\/tr>\n
3<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nAAMI Technical Information Report
Copyright information <\/td>\n<\/tr>\n
5<\/td>\nContents <\/td>\n<\/tr>\n
6<\/td>\nCommittee representation <\/td>\n<\/tr>\n
7<\/td>\nAcknowledgments <\/td>\n<\/tr>\n
8<\/td>\nForeword <\/td>\n<\/tr>\n
9<\/td>\n1 Scope
2 Background
3 Applicability and use
4 Common mode rejection requirement <\/td>\n<\/tr>\n
10<\/td>\n5 Common mode rejection testing
6 History <\/td>\n<\/tr>\n
12<\/td>\nAnnex: CMR Test fixture design & application notes for ECG devices
A.1 Introduction
A.2 Need for this annex
A.3 Construction notes <\/td>\n<\/tr>\n
13<\/td>\nFigure A.1 \u2013 Test circuit for evaluating internal noise and common mode rejection <\/td>\n<\/tr>\n
15<\/td>\nA.4 Calibration notes <\/td>\n<\/tr>\n
17<\/td>\nFigure A.2 \u2013 CMR test line-powered supply and buffer circuit
Figure A.3 \u2013 CMR test generator-powered buffer circuit <\/td>\n<\/tr>\n
18<\/td>\nFigure A.4 – Expanded offset capability CMR fixture <\/td>\n<\/tr>\n
19<\/td>\nA.5 Application notes <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

AAMI TIR60:2014\/(R)2019 – Common mode rejection in ECG monitoring<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
AAMI<\/b><\/a><\/td>\n2014<\/td>\n19<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":198008,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2654],"product_tag":[],"class_list":{"0":"post-198004","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-aami","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/198004","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/198008"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=198004"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=198004"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=198004"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}