IEEE 1826 2012
$46.04
IEEE Standard for Power Electronics Open System Interfaces in Zonal Electrical Distribution Systems Rated Above 100 kW
Published By | Publication Date | Number of Pages |
IEEE | 2012 | 46 |
New IEEE Standard – Active. Open system interfaces for high power electronics equipment used in zonal electrical distribution systems rated above 100 kW are identified in this standard. The required power, monitoring, information exchange, control, and protection interfaces are based on technological maturity, accepted practices, and allowances for future technology insertions. Also, rigorous assessment mechanisms, interface control management, and proactive conformance testing that shall be used to verify and validate open systems to enable plug-and-play operability independently of the components’ origin are defined. Airports, hospitals, major data processing centers (especially those using uninterruptible power supply), broadcast systems, and maritime vessels and platforms are applications covered by this standard. Existing terrestrial utility power systems that do not yet contain the electronic power interfaces and high-speed communication networks that are essential to use this standard shall be upgraded by its application.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 1826-2012 Front Cover |
3 | Title Page |
6 | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata |
7 | Patents |
8 | Participants |
10 | Introduction |
11 | Contents |
13 | IMPORTANT NOTICE 1. Overview 1.1 Scope 1.2 Purpose |
14 | 1.3 Application and limitations 1.4 Intent 2. Normative references |
15 | 3. Definitions, abbreviations, and acronyms 3.1 Definitions |
16 | 3.2 Abbreviations and acronyms 4. Zonal electrical distribution system (ZEDS) fundamentals 4.1 Introduction |
18 | 4.2 Zonal distribution system elements |
20 | 4.3 Quality of service (QoS) |
21 | 4.4 Power system equipment general requirements |
23 | 4.5 Architectural principles 5. Monitoring, information exchange, control, and protection interfaces 5.1 Introduction |
24 | 5.2 Functionality |
25 | 5.3 Interfaces |
27 | 6. Electric power interfaces 6.1 Introduction 6.2 Power interface standards |
28 | 6.3 Electrical power interface ratings |
29 | 6.4 Power interfaces at the zonal boundary |
30 | 6.5 Power interfaces for the in-zone distribution bus 7. Verification and validation (V&V) 7.1 General |
31 | 7.2 Activity: Concept Verification |
32 | 7.3 Activity: Requirements Verification |
34 | 7.4 Activity: Design Verification |
36 | 7.5 Activity: First Article V&V |
38 | 7.6 Activity: Integration Testing |
39 | 7.7 Activity: Qualification Testing |
40 | 7.8 Activity: Commissioning Testing |
41 | 7.9 Activity: Acceptance Testing |
42 | 8. Maintenance of open systems interfaces |
43 | Annex A (informative) Examples of applications of zonal electrical distribution systems (ZEDS) A.1 Naval Destroyer ZEDS |
44 | A.2 Distributed resources islands in the terrestrial power grid |
45 | Annex B (informative) Bibliography |