CA EnergyCode 2013

$27.63

California Energy Code, Title 24 Part 6 (W/ ERRATA & SUPPLEMENT)

Published By Publication Date Number of Pages
CA 2013 159
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The California Energy Code (CEC) contains energy conservation standards applicable to most residential and nonresidential buildings throughout California, including schools.

PDF Catalog

PDF Pages PDF Title
1 2013 CALIFORNIA ENERGY CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 6
2 2013 CALIFORNIA ENERGY CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 6 TITLE PAGE
3 COPYRIGHT
4 PREFACE
ACKNOWLEDGEMENTS
6 CALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST
8 HOW TO DETERMINE WHERE CHANGES HAVE BEEN MADE
10 TABLE OF CONTENTS
12 SUBCHAPTER 1 ALL OCCUPANCIES—GENERAL PROVISIONS
SECTION 100.0 SCOPE
13 TABLE 100.0-A—APPLICATION OF STANDARDS
15 SECTION 100.1 DEFINITIONS AND RULES OF CONSTRUCTION
36 SECTION 100.2 CALCULATION OF TIME DEPENDENT VALUATION (TDV) ENERGY
37 FIGURE 100.1-A CALIFORNIA CLIMATE ZONES
38 SUBCHAPTER 2 ALL OCCUPANCIES—MANDATORY REQUIREMENTS FOR THE MANUFACTURE, CONSTRUCTION AND INSTALLATION OF SYSTEMS, EQUIPMENT AND BUILDING COMPONENTS
SECTION 110.0 SYSTEMS AND EQUIPMENT—GENERAL
SECTION 110.1 MANDATORY REQUIREMENTS FOR APPLIANCES
SECTION 110.2 MANDATORY REQUIREMENTS FOR SPACE-CONDITIONING EQUIPMENT
40 TABLE 110.2-A ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS – MINIMUM EFFICIENCY REQUIREMENTS
41 TABLE 110.2-B UNITARY AND APPLIED HEAT PUMPS, MINIMUM EFFICIENCY REQUIREMENTS
42 TABLE 110.2-C AIR-COOLED GAS-ENGINE HEAT PUMPS
TABLE 110.2-D WATER CHILLING PACKAGES—MINIMUM EFFICIENCY REQUIREMENTSa, b
43 TABLE 110.2-E PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS— MINIMUM EFFICIENCY REQUIREMENTS
TABLE 110.2-F HEAT TRANSFER EQUIPMENT
44 TABLE 110.2-G PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT
TABLE 110.2-H ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW (VRF) AIR CONDITIONERS MINIMUM EFFICIENCY REQUIREMENTS
45 TABLE 110.2-I ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AIR-TO-AIR AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS
46 TABLE 110.2-J WARM-AIR FURNACES AND COMBINATION WARM-AIR FURNACES/AIR-CONDITIONING UNITS, WARM-AIR DUCT FURNACES, AND UNIT HEATERSc,f
TABLE 110.2-K GAS- AND OIL-FIRED BOILERS, MINIMUM EFFICIENCY REQUIREMENTS
47 SECTION 110.3 MANDATORY REQUIREMENTS FOR SERVICE WATER-HEATING SYSTEMS AND EQUIPMENT
48 SECTION 110.4 MANDATORY REQUIREMENTS FOR POOL AND SPA SYSTEMS AND EQUIPMENT
SECTION 110.5 NATURAL GAS CENTRAL FURNACES, COOKING EQUIPMENT, AND POOL AND SPA HEATERS: PILOT LIGHTS PROHIBITED
SECTION 110.6 MANDATORY REQUIREMENTS FOR FENESTRATION PRODUCTS AND EXTERIOR DOORS
50 TABLE 110.6-A DEFAULT FENESTRATION PRODUCT U-FACTORS
TABLE 110.6-B DEFAULT SOLAR HEAT GAIN COEFFICIENT
51 SECTION 110.7 MANDATORY REQUIREMENTS TO LIMIT AIR LEAKAGE
SECTION 110.8 MANDATORY REQUIREMENTS FOR INSULATION, ROOFING PRODUCTS AND RADIANT BARRIERS
52 TABLE 110.8-A SLAB INSULATION REQUIREMENTS FOR HEATED SLAB-ON-GRADE
TABLE 110.8-B VALUES OF SOILING RESISTANCE BY PRODUCT TYPE
53 TABLE 110.8-C MINIMUM PERFORMANCE REQUIREMENTS FOR LIQUID APPLIED ROOF COATINGS
SECTION 110.9 MANDATORY REQUIREMENTS FOR LIGHTING CONTROL DEVICES AND SYSTEMS, BALLASTS AND LUMINAIRES
55 SECTION 110.10 MANDATORY REQUIREMENTS FOR SOLAR READY BUILDINGS
58 SUBCHAPTER 3 NONRESIDENTIAL, HIGH-RISE RESIDENTIAL HOTEL/MOTEL OCCUPANCIES, AND COVERED PROCESSES—MANDATORY REQUIREMENTS
SECTION 120.0 GENERAL
SECTION 120.1 REQUIREMENTS FOR VENTILATION
60 TABLE 120.1-A MINIMUM VENTILATION RATES
SECTION 120.2 REQUIRED CONTROLS FOR SPACE-CONDITIONING SYSTEMS
63 SECTION 120.3 REQUIREMENTS FOR PIPE INSULATION
EQUATION INSULATION THICKNESS
TABLE 120.3-A PIPE INSULATION THICKNESS
64 SECTION 120.4 REQUIREMENTS FOR AIR DISTRIBUTION SYSTEM DUCTS AND PLENUMS
65 SECTION 120.5 REQUIRED NONRESIDENTIAL MECHANICAL SYSTEM ACCEPTANCE
SECTION 120.6 MANDATORY REQUIREMENTS FOR COVERED PROCESSES
66 TABLE 120.6-A REFRIGERATED WAREHOUSE INSULATION
TABLE 120.6-B FAN-POWERED CONDENSERS – MINIMUM EFFICIENCY REQUIREMENTS
68 TABLE 120.6-C FAN-POWERED CONDENSERS – SPECIFIC EFFICIENCY REQUIREMENTS
70 SECTION 120.7 MANDATORY INSULATION REQUIREMENTS
71 SECTION 120.8 BUILDING COMMISSIONING
72 SECTION 120.9 MANDATORY REQUIREMENTS FOR COMMERCIAL BOILERS
74 SUBCHAPTER 4 NONRESIDENTIAL, HIGH-RISE RESIDENTIAL AND HOTEL/MOTEL OCCUPANCIES—MANDATORY REQUIREMENTS FOR LIGHTING SYSTEMS AND EQUIPMENT, AND ELECTRICAL POWER DISTRIBUTION SYSTEMS
SECTION 130.0 LIGHTING CONTROLS ANDEQUIPMENT—GENERAL
75 SECTION 130.1 INDOOR LIGHTING CONTROLS THAT SHALL BE INSTALLED
79 TABLE 130.1-A MULTILEVEL LIGHTING CONTROLS AND UNIFORMITY REQUIREMENTS
80 SECTION 130.2 OUTDOOR LIGHTING CONTROLS AND EQUIPMENT
81 TABLE 130.2-A UPLIGHT RATINGS (Maximum Zonal Lumens)
TABLE 130.2-B GLARE RATINGS (Maximum Zonal Lumens)
SECTION 130.3 SIGN LIGHTING CONTROLS
SECTION 130.4 LIGHTING CONTROL ACCEPTANCE AND INSTALLATION CERTIFICATE REQUIREMENTS
82 SECTION 130.5 ELECTRICAL POWER DISTRIBUTION SYSTEMS
84 TABLE 130.5-A MINIMUM REQUIREMENTS FOR METERING OF ELECTRICAL LOAD
TABLE 130.5-B MINIMUM REQUIREMENTS FOR SEPARATION OF ELECTRICAL LOAD
86 SUBCHAPTER 5 NONRESIDENTIAL, HIGH-RISE RESIDENTIAL AND HOTEL/MOTEL OCCUPANCIES—PERFORMANCE AND PRESCRIPTIVE COMPLIANCE APPROACHES FOR ACHIEVING ENERGY EFFICIENCY
SECTION 140.0 PERFORMANCE AND PRESCRIPTIVE COMPLIANCE APPROACHES
SECTION 140.1 PERFORMANCE APPROACH: ENERGY BUDGETS
SECTION 140.2 PRESCRIPTIVE APPROACH
SECTION 140.3 PRESCRIPTIVE REQUIREMENTS FOR BUILDING ENVELOPES
87 TABLE 140.3 ROOF/CEILING INSULATION TRADE OFF FOR AGED SOLAR REFLECTANCE
88 EQUATION 140.3-A RELATIVE SOLAR HEAT GAIN, COEFFICIENT, RSHGC
EQUATION 140.3-B VERTICAL FENESTRATION MINIMUM VT
90 TABLE 140.3-A MATERIALS DEEMED TO COMPLY WITH SECTION 140.3(a)9A
91 TABLE 140.3-B PRESCRIPTIVE ENVELOPE CRITERIA FOR NONRESIDENTIAL BUILDINGS(INCLUDING RELOCATABLE PUBLIC SCHOOL BUILDINGS WHERE MANUFACTURER CERTIFIES USE ONLY IN SPECIFIC CLIMATE ZONE; NOT INCLUDING HIGH-RISE RESIDENTIAL BUILDINGS AND GUEST ROOMS OF HOTEL/MOTEL BUILDINGS)
92 TABLE 140.3-C PRESCRIPTIVE ENVELOPE CRITERIA FOR HIGH-RES BUILDINGS AND GUEST ROOMS OF HOTEL/MOTEL BUILDINGS
93 TABLE 140.3-D PRESCRIPTIVE ENVELOPE CRITERIA FOR RELOCATABLE PUBLIC SCHOOL BUILDINGS FOR USE IN ALL CLIMATE ZONES
SECTION 140.4 PRESCRIPTIVE REQUIREMENTS FOR SPACE-CONDITIONING SYSTEMS
94 EQUATION 140.4-A ADJUSTED TOTAL-FAN POWER INDEX
96 TABLE 140.4-A ECONOMIZER TRADE-OFF TABLE FOR COOLING SYSTEMS
TABLE 140.4-B AIR ECONOMIZER HIGH LIMIT SHUT OFF CONTROL REQUIREMENTS
97 TABLE 140.4-C DIRECT EXPANSION (DX) UNIT REQUIREMENTS FOR COOLING STAGES AND COMPRESSOR DISPLACEMENT
99 TABLE 140.4-D EFFECTIVE DATES FOR FAN CONTROL SYSTEMS
SECTION 140.5 PRESCRIPTIVE REQUIREMENTS FOR SERVICE WATER-HEATING SYSTEMS
100 SECTION 140.6 PRESCRIPTIVE REQUIREMENTS FOR INDOOR LIGHTING
108 TABLE 140.6-A LIGHTING POWER DENSITY ADJUSTMENT FACTORS (PAF)
TABLE 140.6-B COMPLETE BUILDING METHOD-LIGHTING POWER DENSITY VALUES
109 TABLE 140.6-C AREA CATEGORY METHOD – LIGHTING POWER DENSITY VALUES (WATTS/FT²)
110 TABLE 140.6-D TAILORED METHOD LIGHTING POWER ALLOWANCES
TABLE 140.6-E ADJUSTMENTS FOR MOUNTING HEIGHT ABOVE FLOOR
TABLE 140.6-F ROOM CAVITY RATIO (RCR) EQUATIONS
111 TABLE 140.6-G ILLUMINANCE LEVEL (LUX) POWER DENSITY VALUES (WATTS/FT2)
SECTION 140.7 REQUIREMENTS FOR OUTDOOR LIGHTING
112 TABLE 140.7-A GENERAL HARDSCAPE LIGHTING POWER ALLOWANCE
113 TABLE 140.7-B ADDITIONAL LIGHTING POWER ALLOWANCE FOR SPECIFIC APPLICATIONS All area and distance measurements in plan view unless otherwise noted.
114 SECTION 140.8 REQUIREMENTS FOR SIGNS
SECTION 140.9 PRESCRIPTIVE REQUIREMENTS FOR COVERED PROCESSES
115 TABLE 140.9-A MAXIMUM NET EXHAUST FLOW RATE, CFM PER LINEAR FOOT OF HOOD LENGTH
118 SUBCHAPTER 6 NONRESIDENTIAL, HIGH-RISE RESIDENTIAL AND HOTEL/MOTEL OCCUPANCIES—ADDITIONS, ALTERATIONS AND REPAIRS
SECTION 141.0 ADDITIONS, ALTERATIONS AND REPAIRSTO EXISTING BUILDINGS THAT WILL BE NONRESIDENTIAL, HIGH-RISE RESIDENTIAL AND HOTEL/MOTEL OCCUPANCIES AND TO EXISTING OUTDOOR LIGHTING FOR THESE OCCUPANCIES AND TO INTERNALLY AND EXTERNALLY ILLUMINATED SIGNS
119 TABLE 141.0-A ALTERED WINDOW MAXIMUM U-FACTOR AND MINIMUM RSHGC
120 TABLE 141.0-B ROOF/CEILING INSULATION TRADEOFF FOR AGED SOLAR REFLECTANCE
TABLE 141.0-C INSULATION REQUIREMENTS FOR ROOF ALTERATIONS
124 TABLE 141.0-D THE STANDARD DESIGN FOR AN ALTERED COMPONENT
SECTION 141.1 REQUIREMENTS FOR COVERED PROCESSES IN ADDITIONS, ALTERATIONS TO EXISTING BUILDINGS THAT WILL BE NONRESIDENTIAL, HIGH-RISE RESIDENTIAL, AND HOTEL/MOTEL OCCUPANCIES
125 TABLE 141.0-E REQUIREMENTS FOR LUMINAIRE ALTERATIONS
TABLE 141.0-F REQUIREMENTS FOR LUMINAIRE MODIFICATIONS-IN-PLACE
126 SUBCHAPTER 7 LOW-RISE RESIDENTIAL BUILDINGS—MANDATORY FEATURES AND DEVICES
SECTION 150.0 MANDATORY FEATURES AND DEVICES
128 TABLE 150-A PIPE INSULATION CONDUCTIVITY RANGE
TABLE 150-B PIPE INSULATION MINIMUM THICKNESS REQUIREMENTS
TABLE 150-C HIGH EFFICIENCY LUMINAIRE REQUIREMENTS
135 TABLE 150.0-A CLASSIFICATION OF HIGH-EFFICACY AND LOW-EFFICACY LIGHT SOURCES
TABLE 150.0-B MINIMUM REQUIREMENTS FOR OTHER LIGHT SOURCES TO QUALIFY AS HIGH EFFICACY
TABLE 150.0-C RETURN DUCT SIZING FOR SINGLE RETURN DUCT SYSTEMS
136 TABLE 150.0-D RETURN DUCT SIZING FOR MULTIPLE RETURN DUCT SYSTEMS
138 SUBCHAPTER 8 LOW-RISE RESIDENTIAL BUILDINGS—PERFORMANCE AND PRESCRIPTIVE COMPLIANCE APPROACHES FOR NEWLY CONSTRUCTED RESIDENTIAL BUILDINGS
SECTION 150.1 PERFORMANCE AND PRESCRIPTIVE COMPLIANCE APPROACHES FOR NEWLY CONSTRUCTED RESIDENTIAL BUILDINGS
143 TABLE 150.1-A COMPONENT PACKAGE A-STANDARD BUILDING DESIGN
144 FOOTNOTE REQUIREMENTS TO TABLE 150.1-A:
146 SUBCHAPTER 9 LOW-RISE RESIDENTIAL BUILDINGS—ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS
SECTION 150.2 ENERGY EFFICIENCY STANDARDS FOR ADDITIONS AND ALTERATIONS IN EXISTING BUILDINGS THAT WILL BE LOW-RISE RESIDENTIAL OCCUPANCIES
150 TABLE 150.2-A AGED SOLAR REFLECTANCE INSULATION TRADE OFF TABLE
TABLE 150.2-B STANDARD DESIGN FOR AN ALTERED COMPONENT
151 2010 CALIFORNIA MECHANICAL CODE, CALIFORNIA CODE OF REGULATIONS, TITLE 24, PART 4 CHAPTER 6, DUCT SYSTEMS
TABLE P4-A ADOPTION TABLE
152 APPENDIX 1-A STANDARDS AND DOCUMENTS REFERENCED IN THE ENERGY EFFICIENCY REGULATIONS
AIR-CONDITIONING, HEATING AND REFRIGERATION INSTITUTE
AIR-CONDITIONING CONTRACTORS OF AMERICA
AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (NATIONAL PUBLICATIONS)
153 AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (REGIONAL PUBLICATION)
AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASTM INTERNATIONAL
154 CALIFORNIA BUILDING STANDARDS COMMISSION
CALIFORNIA ENERGY COMMISSION
CALIFORNIA DEPARTMENT OF CONSUMER AFFAIRS
CODE OF FEDERAL REGULATIONS
COOLING TECHNOLOGY INSTITUTE
COOL ROOF RATING COUNCIL
HYDRONICS INSTITUTE
ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA
155 INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS
INTERNATIONAL CODE COUNCIL
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION
NATIONAL FENESTRATION RATING COUNCIL
NFRC 400
NSF INTERNATIONAL
SHEET METAL AND AIR-CONDITIONING CONTRACTORS NATIONAL ASSOCIATION
UNDERWRITERS LABORATORIES
156 HISTORY NOTE APPENDIX
158 ICC EVALUATION SERVICE
159 ICC PLAN REVIEW SERVICES
CA EnergyCode 2013
$27.63