BS EN ISO 2719:2016 – TC:2020 Edition
$217.84
Tracked Changes. Determination of flash point. Pensky-Martens closed cup method
Published By | Publication Date | Number of Pages |
BSI | 2020 | 77 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
47 | European foreword |
49 | Foreword |
50 | Introduction |
52 | 1 Scope 2 Normative references |
53 | 3 Terms and definitions 4 Principle 5 Chemicals and materials 6 Apparatus |
54 | 7 Apparatus preparation 7.1 General 7.2 Location of the apparatus 7.3 Cleaning the test cup 7.4 Apparatus assembly 7.5 Apparatus verification |
55 | 8 Sampling 9 Sample handling 9.1 Petroleum products 9.1.1 Sub-sampling 9.1.2 Samples containing undissolved water 9.1.3 Samples that are liquid at ambient temperature 9.1.4 Samples that are very viscous, semi-solid or solid at ambient temperature |
56 | 9.2 Paints and varnishes 10 Procedure 10.1 General 10.2 Procedure A |
57 | 10.3 Procedure B |
58 | 10.4 Procedure C |
59 | 11 Calculation 11.1 Conversion of barometric pressure reading 11.2 Correction of observed flash point to standard atmospheric pressure 12 Expression of results 13 Precision 13.1 General 13.2 Repeatability, r |
60 | 13.3 Reproducibility, R |
61 | 14 Test report |
62 | Annex A (informative) Apparatus verification |
65 | Annex B (normative) Pensky-Martens closed cup test apparatus |
71 | Annex C (normative) Temperature measuring device specification |
73 | Bibliography |