Email:[email protected]

This part of ISO 10360 specifies the acceptance tests for verifying the performance of a CMM (coordinate measuring machine) when measuring lengths as stated by the manufacturer. It also specifies the reverification tests that enable the user to periodically reverify the performance of the CMM. The acceptance and reverification tests given in this part of ISO 10360 are applicable only to Cartesian CMMs with optical distance sensors. This standard does not explicitly apply to non-Cartesian CMMs, however, the parties may apply this part of 10360 to non-Cartesian CMMs by mutual agreement.

NOTE This part of ISO 10360 is not intended to apply for CMMs whose measuring volume is significantly smaller than the size of the test sphere, however, the principle, artefacts, and procedure of the test described in this part of ISO 10360 are useful for the acceptance and reverification tests of those CMMs either as it is or with modifying the parameters such as the size of the test artefacts and the number of the measurements.

This part of ISO 10360 specifies:

  • performance requirements that can be assigned by the manufacturer or the user of the CMM,

  • the manner of execution of the acceptance and reverification tests to demonstrate the stated requirements,

  • rules for verifying conformance, and

  • applications for which the acceptance and reverification tests can be used.

PDF Catalog

PDF Pages PDF Title
4 Foreword
6 Foreword
7 Introduction
9 Section sec_1
Section sec_2
1 Scope
2 Normative references
10 Section sec_3
Section sec_3.1
Section sec_3.2
Section sec_3.3
Section sec_3.4
3 Terms and definitions
11 Table tab_a
Figure fig_1
Section sec_3.5
12 Table tab_b
Figure fig_2
Table tab_c
Figure fig_3
13 Section sec_3.6
Section sec_3.7
Section sec_3.8
14 Section sec_3.9
Section sec_3.10
Section sec_3.11
15 Section sec_3.12
Section sec_3.13
Section sec_3.14
16 Section sec_3.15
Section sec_3.16
Section sec_3.17
17 Section sec_3.18
Section sec_4
Table tab_1
4 Symbols
18 Section sec_5
Section sec_5.1
Section sec_5.2
5 Requirements for metrological characteristics
5.1 Environmental conditions
5.2 Operating conditions
19 Section sec_5.3
Section sec_5.4
Section sec_5.5
Section sec_5.6
5.3 Probing form error
5.4 Probing dispersion value
5.5 Probing size error
5.6 Probing size error All
20 Section sec_5.7
Section sec_5.8
Section sec_5.9
5.7 Length measurement error
5.8 Flat form measurement error
5.9 Workpiece loading effects
21 Section sec_6
Section sec_6.1
Section sec_6.2
Section sec_6.2.1
Section sec_6.2.2
6 Acceptance tests and reverification tests
6.1 General
6.2 Probing characteristics
22 Table tab_j
Figure fig_4
23 Table tab_k
Figure fig_5
Section sec_6.2.3
Section sec_6.2.3.1
24 Section sec_6.2.3.2
Section sec_6.2.3.3
Section sec_6.2.4
Section sec_6.2.4.1
25 Table tab_l
Figure fig_6
26 Section sec_6.2.4.2
Section sec_6.2.4.2.1
Section sec_6.2.4.2.2
Section sec_6.2.4.2.3
27 Section sec_6.2.4.2.4
Section sec_6.2.4.3
Section sec_6.2.4.3.1
Section sec_6.2.4.3.2
Section sec_6.2.4.3.3
28 Section sec_6.3
Section sec_6.3.1
Section sec_6.3.2
Section sec_6.3.3
6.3 Length measurement error
29 Figure fig_7
Table tab_2
Section sec_6.3.4
30 Section sec_6.3.5
Section sec_6.3.5.1
Section sec_6.3.5.2
31 Section sec_6.3.5.3
Section sec_6.4
Section sec_6.4.1
6.4 Flat form measurement error
32 Section sec_6.4.2
Section sec_6.4.3
33 Figure fig_8
Table tab_3
Section sec_6.4.4
34 Section sec_7
Section sec_7.1
Section sec_7.1.1
Section sec_7.1.2
Section sec_7.1.2.1
7 Compliance with specifications
7.1 Acceptance test
35 Section sec_7.1.2.2
Section sec_7.1.2.3
Section sec_7.1.2.4
Section sec_7.1.2.5
Section sec_7.1.2.6
Section sec_7.2
7.2 Reverification test
36 Section sec_8
Section sec_8.1
Section sec_8.2
Section sec_8.3
Section sec_9
Table tab_4
8 Applications
8.1 Acceptance test
8.2 Reverification test
8.3 Interim check
9 Indication in product documentation and data sheets
37 Annex sec_A
Annex sec_A.1
Annex sec_A.2
Annex sec_A.2.1
Annex sec_A.2.2
Annex A
(informative)

Structural resolution test

38 Figure fig_A.1
Annex sec_A.2.3
Figure fig_A.2
Annex sec_A.2.4
39 Figure fig_A.3
Annex sec_A.3
40 Figure fig_A.4
41 Table tab_m
Figure fig_A.5
42 Annex sec_B
Annex sec_B.1
Annex B
(normative)

Artefacts that represent a calibrated test length

43 Annex sec_B.2
Annex sec_B.2.1
44 Table tab_n
Figure fig_B.1
Annex sec_B.2.2
Annex sec_B.2.3
Annex sec_B.2.4
45 Annex sec_B.2.5
Annex sec_B.3
Annex sec_B.3.1
46 Table tab_o
Figure fig_B.2
Annex sec_B.3.2
Annex sec_B.3.3
47 Annex sec_B.3.4
Annex sec_B.3.5
Annex sec_B.4
Annex sec_B.4.1
48 Table tab_p
Figure fig_B.3
Annex sec_B.4.2
49 Annex sec_B.4.3
Annex sec_B.4.3.1
Annex sec_B.4.3.2
50 Annex sec_B.4.3.3
Annex sec_B.4.3.4
Annex sec_B.4.3.5
52 Annex sec_C
Annex sec_C.1
Annex sec_C.2
Annex sec_C.3
Annex C
(informative)

Alignment of artefacts

53 Figure fig_C.1
Figure fig_C.2
54 Annex sec_D
Annex sec_D.1
Annex sec_D.2
Table tab_D.1
Annex sec_D.3
Annex sec_D.3.1
Annex sec_D.3.2
Annex sec_D.3.3
Annex D
(normative)

Articulated location value of CMMs with articulating probing system for optical distance sensors

55 Table tab_q
Figure fig_D.1
Annex sec_D.3.4
Annex sec_D.4
Annex sec_D.4.1
Annex sec_D.4.1.1
Annex sec_D.4.1.2
56 Annex sec_D.4.2
Annex sec_D.5
Annex sec_D.5.1
Annex sec_D.5.2
Annex sec_D.5.3
Annex sec_D.6
Table tab_D.2
57 Annex sec_E
Annex sec_E.1
Annex sec_E.2
Annex sec_E.3
Annex E
(informative)

Relation to the GPS matrix model

58 Table tab_E.1
Annex sec_E.4
59 Reference ref_1
Reference ref_2
Reference ref_3
Reference ref_4
Reference ref_5
Reference ref_6
Bibliography
Bibliography