BS EN 62386-209:2011
$215.11
Digital addressable lighting interface – Particular requirements for control gear. Colour control (device type 8)
Published By | Publication Date | Number of Pages |
BSI | 2011 | 206 |
IEC 62386-209:2011 specifies a protocol and test procedures for the control by digital signals of electronic control gear that can change their light colour. This publication contains .pdf files, which reproduce the test sequences illustrated in Figures 5 to 127. These files are intended to be used as a complement and do not form an integral part of the publication. This publication is to be read in conjunction with /2 and /2.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
12 | INTRODUCTION |
13 | 1 Scope 2 Normative references 3 Terms and definitions |
15 | 4 General 4.4 Colour type |
16 | Figures Figure 1 – The CIE color space chromaticity diagram, 1931 Cambridge University Press |
17 | Figure 2 – Black body line Figure 3 – Colour temperature diagram |
18 | 5 Electrical specification 6 Interface power supply 7 Transmission protocol Structure 8 Timing 9 Method of operation 9.1 Logarithmic dimming curve, arc power levels and accuracy |
20 | 9.2 Power on Tables Table 1 – Power on |
21 | 9.3 Interface-failure Table 2 – Interface failure |
22 | 9.4 Min and max level 9.5 Fade time and fade rate 9.6 Reaction to commands during error state 9.9 16 Bit data transfer for the application extended control commands 9.10 Multi colour type control gear Table 3 – Min and Max level |
23 | 9.11 Colour scenes Table 4 – Colour scenes |
24 | 9.12 Colour change |
26 | Table 5 – System reaction on DAPC and TEMPORARY COLOUR TYPE Table 6 – System reaction on commands and colour type |
28 | 9.13 Colour temperature Tc limits |
29 | 10 Declaration of variables Table 7 – Tc limit change behaviour |
30 | Table 8 – Declaration of variables |
32 | 11 Definition of commands 11.1 Arc power control commands |
33 | 11.2 Configuration commands |
34 | 11.3 Query commands |
38 | Figure 4 – Application extended configuration command sequence example |
39 | Table 9 – Store colour temperature Tc limit Table 10 – Assign channel to colour |
41 | Table 11 – Query colour value |
44 | 11.4 Special commands 11.5 Summary of the command set Table 12 – Query assigned colour Table 13 – Summary of the extended application command set |
46 | Table 14 – Command versus colour type cross-reference |
47 | Table 15 – Command versus the DTR, DTR1 and DTR2 cross-reference |
48 | 12 Test procedures 12.2 Test sequences ‘Configuration commands’ |
49 | Figure 5 – Test sequence “RESET” |
50 | Figure 6 – Test sequence “testResetDefault (Colour Type)” |
52 | Figure 7 – Test sequence “testReset_xy” |
54 | Figure 8 – Test sequence “testReset_Tc” |
56 | Figure 9 – Test sequence “testReset_PrimaryN” |
59 | Figure 11 – Test sequence “testResetNoChange_xy” |
61 | Figure 12 – Test sequence “testResetNoChange_Tc” |
63 | Figure 13 – Test sequence “testResetNoChange_PrimaryN” |
64 | Figure 14 – Test sequence “testResetNoChange_RGBWAF” |
65 | Figure 15 – Test sequence “testResetIndependentColourType” |
66 | Figure 16 – Test sequence “Save_PrimaryN” |
67 | Figure 17 – Test sequence “Restore_PrimaryN (xPrimary, yprimary, TYPrimary” |
68 | 12.7 Test sequences ‘Application extended commands for device type 8’ Figure 18 – Test sequence “QUERY GEAR FEATURES/STATUS” |
70 | Figure 19 – Test sequence “QUERY COLOUR STATUS” |
71 | Figure 20 – Test sequence “ActivateAndCheck (ColourType, curActive)” |
73 | Figure 21 – Test sequence “xyOutOfRangeCheck( )” |
74 | Figure 22 – Test sequence “TcOutOfRangeCheck” |
75 | Figure 23 – Test sequence “CheckOnlyOneColourTypeActive” |
76 | Figure 24 – Test sequence “TcOutOfRangePhysWarmest” |
77 | Figure 25 – Test sequence “TcOutOfRangeCheckPhysCoolest” |
78 | Figure 26 – Test sequence ‘QUERY COLOUR TYPE FEATURES’ |
79 | Table 16 – Command returns to test sequence “QUERY COLOUR VALUE” |
81 | Figure 27 – Test sequence ‘QUERY COLOUR VALUE’ |
83 | Figure 28 – Test sequence “QUERY RGBWAF CONTROL” |
84 | Figure 29 – test sequence “QUERY ASSIGNED COLOUR” |
86 | Figure 30 – Test sequence “STORE TY PRIMARY N” |
87 | Figure 31 – Test sequence “CheckDTR2Behaviour8(nrPrim)” |
89 | Figure 32 – Test sequence “STORE xy-COORDINATE PRIMARY N” |
91 | Figure 33 – Test sequence “CheckDTR2Behaviour_XY(nrPrim)” |
92 | Figure 34 – Test sequence “STORE COLOUR TEMPERATURE Tc LIMIT” |
93 | Figure 35 – Test sequence “TcCheckDTR2Behaviour( )” |
94 | Figure 36 – Test sequence “TcSavePhysicalLimits” |
95 | Figure 37 – Test sequence “TcRestorePhysicalLimits(phLimits) |
97 | Figure 38 – Test sequence “TcCheckLimits” |
98 | Figure 39 – Test sequence “STORE GEAR FEATURES/STATUS” |
99 | Figure 40 – Test sequence “AUTOMATIC ACTIVATE” |
100 | Figure 41 – Test sequence “AutoActivate_xy(min_level, command, delay, expected_level)” |
101 | Figure 42 – Test sequence “NoAutoActivate_xy(min_level, command, delay, expected_level)” |
102 | Figure 43 – Test sequence “AutoActivate_Tc(min_level, command, delay, expected_level)” |
103 | Figure 44 – Test sequence “NoAutoActivate_Tc(min_level, command, delay, expected_level)” |
104 | Figure 45 – Test sequence “AutoActivate_PrimaryN(min_level, command, delay, expected_level)” |
105 | Figure 46 – Test sequence “NoAutoActivate_PrimaryN(min_level, command, delay, expected_level)” |
106 | Figure 47 – Test sequence “AutoActivate_RGBWAF(min_level, command, delay, expected_level)” |
107 | Figure 48 – Test sequence “NoAutoActivate_RGBWAF(min_level, command, delay, expected_level)” |
108 | Figure 49 – Test sequence “AutoActivate_Dapc0” |
109 | Figure 50 – Test sequence “AutoActivate_Off” |
110 | Figure 51 – Test sequence “Load_xy_Coordinate (point_x, point_y)” |
111 | Figure 52 – Test sequence “Get_actual_xy ( )” |
112 | Figure 53 – Test sequence “findTwoValid_Tc_Points ( )” |
113 | Figure 54 – Test sequence “Load_Tc (Tc_value)” |
114 | Figure 55 – Test sequence “Get_actual_Tc ( )” |
115 | Figure 56 – Test sequence “findTwoValid_PrimaryN_Points ( )” |
116 | Figure 57 – Test sequence “Load_PrimaryN(point_PrimaryN)” |
117 | Figure 58 – Test sequence “Get_actual_PrimaryN ( )” |
118 | Figure 59 – Test sequence “findTwoValid_RGBWAF_Pionts ( )” |
119 | Figure 60 – Test sequence “Load_RGBWAF(point_RGBWAF)” |
120 | Figure 61 – Test sequence “Get_actual_RGBWAF ( )” |
121 | Figure 62 – Test sequence “ToggleAutoActivation(auto)” |
122 | Figure 63 – Test sequence “ASSIGN COLOUR TO LINKED CHANNEL” |
124 | Figure 64 – Test sequence “START AUTO CALIBRATION” |
125 | Figure 65 – Test sequence “POWER ON COLOUR” |
127 | Figure 66 – Test sequence “PowerOnBehaviour_xy” |
129 | Figure 67 – Test sequence “PowerOnBehaviour_Tc” |
131 | Figure 68 – Test sequence “PowerOnBehaviour_PrimaryN” |
133 | Figure 69 – Test sequence “PowerOnBehaviour_RGBWAF” |
134 | Figure 70 – Test sequence “PowerOnBehaviourMask_xy” |
135 | Figure 71 – Test sequence “PowerOnBehaviourMask_Tc” |
137 | Figure 72 – Test sequence “PowerOnBehaviourMask_PrimaryN” |
139 | Figure 73 – Test sequence “PowerOnBehaviourMask_RGBWAF” |
141 | Figure 74 – Test sequence “SYSTEM FAILURE” |
143 | Figure 75 – Test sequence “SystemFailureBehaviour_xy” |
145 | Figure 76 – Test sequence “SystemFailureBehaviour_Tc” |
147 | Figure 77 – Test sequence “SystemFailureBehaviourPrimaryN” |
149 | Figure 78 – Test sequence “SystemFailureBehaviour_RGBWAF” |
150 | Figure 79 – Test sequence “SystemFailureBehaviourMask_xy” |
151 | Figure 80 – Test sequence “SystemFailureBehaviourMask_Tc” |
153 | Figure 81 – Test sequence “SystemFailureBehaviourMask_PrimaryN” |
155 | Figure 82 – Test sequence “SystemFailureBehaviourMask_RGBWAF” |
157 | Figure 83 – Test sequence “STORE THE DTR AS SCENE XXXX/ GOTO SCENE XXXX” |
158 | Figure 84 – Test sequence “SetTemporaries (col, val)” |
160 | Figure 85 – Test sequence “ENABLE DEVICE TYPE: Application extended commands” |
161 | Figure 86 – Test sequence “ENABLE DEVICE TYPE:Application extended configuration commands” |
162 | Figure 87 – Test sequence “SET TEMPORARY x-COORDINATE” |
163 | Figure 88 – Test sequence “SET TEMPORARY y-COORDINATE” |
164 | Figure 89 – Test sequence “ACTIVATE” |
165 | Figure 90 – Test sequence “FindTwoValid_xy_Points(point1_x, point1_y, point2_x, point2_y)” |
166 | Figure 91 – Test sequence “Goto_xy_Coordinate (Point_x, point_y)” |
167 | Figure 92 – Test sequence “x-COORDINATE STEP UP” |
168 | Figure 93 – Test sequence “ActivateColourType (Colour Type)” |
169 | Figure 94 – Test sequence “x-COORDINATE STEP DOWN” |
170 | Figure 95 – Test sequence “Get MainPointxy ( )” |
171 | Figure 96 – Test sequence “GetCurrentPointxy ( )” |
172 | Figure 97 – Test sequence “xymodeGetMainPointxy ( )” |
173 | Figure 98 – Test sequence “SET TEMPORARY COLOUR TEMPERATURE Tc” |
174 | Figure 99 – Test sequence “FindValidTcValue (TcValue)” |
175 | Figure 100 – Test sequence “CheckAllTcValues ( )” |
176 | Figure 101 – Test sequence “COLOUR TEMPERATURE Tc STEP COOLER” |
177 | Figure 102 – Test sequence “COLOUR TEMPERATURE Tc STEP WARMER” |
178 | Figure 103 – Test sequence “SET TEMPORARY PRIMARY N DIMLEVEL” |
179 | Figure 104 – Test sequence “CheckPrimaryNFadingBehaviour (nPrim)” |
180 | Figure 105 – Test sequence “SET TEMPORARY RGB DIMLEVEL” |
181 | Figure 106 – Test sequence “CheckRGBFadingBehaviour ( )” |
182 | Figure 107 – Test sequence “SET TEMPORARY WAF DIMLEVEL |
183 | Figure 108 – Test sequence “CheckWAFFadingBehaviour ( )” |
184 | Figure 109 – Test sequence “SET RGBWAF CONTROL” |
185 | Figure 110 – Test sequence “Chan_Col_Control_ActivationTest (nrChan)” |
186 | Figure 111 – Test sequence “Norm_Col_Control_ActivationTest ( )” |
187 | Figure 112 – Test sequence “Transition_To_Inactive_Test ( )” |
188 | Figure 113 – Test sequence “COPY REPORT TO TEMPORARY” |
189 | Figure 114 – Test sequence “Copy_xy ( )” |
190 | Figure 115 – Test sequence “Copy_Tc ( )” |
191 | Figure 116 – Test sequence “Copy_PrimaryN ( )” |
192 | Figure 117 – Test sequence “Copy_RGBWAF ( )” |
193 | Figure 118 – Test sequence “PrimaryN_Check1 (nrPrim)” |
194 | Figure 119 – Test sequence “PrimaryN_Check2 (nrPrim)” |
195 | Figure 120 – Test sequence “RGBWAF_Check1 (nrChan)” |
196 | Figure 121 – Test sequence “RGBWAF_Check2 (nrChan)” |
197 | Figure 122 – Test sequence “QUERY EXTENDED VERSION NUMBER” |
198 | Figure 123 – Test sequence “RESERVED APPLICATION EXTENDED COMMANDS” |
199 | 13 General subsequences 13.1 Test sequence “Set16bitValue (val)” Figure 124 – “Set16bitValue (val)” |
200 | 13.2 Test sequence “SetSpecific16bitValue (val)” Figure 125 – Test sequence “SetSpecific16bitValue (val)” |
201 | 13.3 Test sequence “Get16bitValue ( )” Figure 126 – Test sequence “Get16bitValue ( )” |
202 | 13.4 Test sequence “Get16bitColourValue ( )” Figure 127 – Test sequence “Get16bitColourValue ( )” |
203 | Bibliography |