BS EN 17609:2022:2023 Edition

$215.11

Building automation and control systems. Control applications

Published By Publication Date Number of Pages
BSI 2023 160
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 undefined
12 1 Scope
2 Normative references
3 Terms and definitions
14 4 Abbreviations
16 5 Functional specifications having an impact on energy performance, comfort, and operational requirements of buildings
5.1 Heating control
5.1.1 Emission control
5.1.1.1 Type 1 – Central automatic control
17 5.1.1.2 Type 2 – Individual room control
18 5.1.1.3 Type 3 – Individual modulating room control with communication
19 5.1.1.4 Type 4 – Individual modulating room control with communication and occupancy detection
20 5.1.2 Emission control for TABS (heating mode)
5.1.2.1 Type 1 – Central automatic control
5.1.2.2 Type 2 – Advanced central automatic control
21 5.1.2.3 Type 3 – Advanced central automatic control with intermittent operation and/or room temperature feedback control
23 5.1.3 Control of distribution network hot water temperature (supply or return)
5.1.3.1 Type 1 – Outside air temperature compensated control
5.1.3.2 Type 2 – Demand based control
24 5.1.4 Control of distribution pumps in networks
5.1.4.1 Type 1 – On/Off control
25 5.1.4.2 Type 2 – Multi stage control
26 5.1.4.3 Type 3 – Variable speed pump control (pump unit (internal) estimations)
27 5.1.4.4 Type 4 – Variable speed pump control (external demand signal)
5.1.5 Intermittent control of emission and/or distribution
5.1.5.1 Type 1 – Automatic Control with fixed Time Program
29 5.1.5.2 Type 2 – Automatic control with Optimum Start/Stop
30 5.1.5.3 Type 3 – Automatic control with demand evaluation
31 5.1.6 Heat generator control (combustion and district heating)
5.1.6.1 Type 1 – Variable temperature control depending on outside temperature
5.1.6.2 Type 2 – Variable temperature control depending on the load
32 5.1.7 Heat generator control (heat pump)
5.1.7.1 Type 1 -Variable temperature depending on outdoor temperature
33 5.1.7.2 Type 2 – Variable temperature depending on the load
34 5.1.8 Heat generator control (outdoor unit)
5.1.8.1 Type 1 -Multi-stage control of heat generator depending on the load or demand
5.1.8.2 Type 2 -Variable control of heat generator capacity depending on the load or demand
35 5.1.9 Sequencing of different heat generators
5.1.9.1 Type 1 – Control according to fixed priority list
36 5.1.9.2 Type 2 – Control according to dynamic priority list based on generator efficiency and capacity
37 5.1.9.3 Type 3 – Control according to dynamic priority list based on predicted and current load, efficiency and capacity of generators
5.1.10 Control of Thermal Energy Storage (TES) charging
5.1.10.1 Type 1 – 2-sensor charging of storage
38 5.1.10.2 Type 2 – Load prediction based storage operation
5.1.11 Hydronic balancing heating distribution (including contribution to balancing to the emission side)
5.1.11.1 Type 1 – Balanced statically per emitter, without group balance
39 5.1.11.2 Type 2 – Balanced statically per emitter, and a static group balance
40 5.1.11.3 Type 3 – Balanced statically per emitter and dynamic group balance
5.1.11.4 Type 4 – Balanced dynamically per emitter
41 5.2 Domestic hot water supply control
5.2.1 Control of DHW storage charging with direct electric heating or integrated electric heat pump
5.2.1.1 Type 1 – Automatic control on/off and scheduled charging enable
42 5.2.1.2 Type 2 – Automatic on/off control and scheduled charging enable and multi-sensor storage management
5.2.2 Control of DHW storage charging using hot water generation
5.2.2.1 Type 1 – Automatic on/off control and scheduled charging enable
43 5.2.2.2 Type 2 – Automatic on/off control and scheduled charging enable and demand-based supply temperature control or multi-sensor storage management
44 5.2.3 Control of DHW storage charging with solar collector and supplementary heat generation
5.2.3.1 Type 1 – Automatic control of solar storage charge (Prio. 1) and supplementary storage charge (Prio. 2)
45 5.2.3.2 Type 2 – Automatic control of solar storage charge (Prio. 1) and supplementary storage charge (Prio. 2) plus demand based supply temperature control or multi-sensor storage management
46 5.2.4 Control of DHW circulation pump
5.2.4.1 Type 1 – Control of DHW circulation pump, with time switch program
47 5.3 Cooling control
5.3.1 Emission Control
5.3.1.1 Type 1 – Central automatic control
48 5.3.1.2 Type 2 – Individual room control
5.3.1.3 Type 3 – Individual modulating room control with communication
49 5.3.1.4 Type 4 – Individual modulating room control with communication and occupancy detection
50 5.3.2 Emission control for TABS (cooling mode)
5.3.2.1 Type 1 – Central automatic control
51 5.3.2.2 Type 2 – Advanced central automatic control
52 5.3.2.3 Type 3 – Advanced central automatic control with intermittent operation and/or room temperature feedback control
53 5.3.3 Control of distribution network chilled water temperature (supply or return)
5.3.3.1 Type 1 – Outside temperature compensated control
5.3.3.2 Type 2 – Demand based control
54 5.3.4 Control of distribution pumps in hydraulic networks
5.3.4.1 Type 1 – On/Off control
55 5.3.4.2 Type 2 – Multi-stage control
5.3.4.3 Type 3 – Variable speed pump control (pump unit (internal) estimations)
56 5.3.4.4 Type 4 – Variable speed pump control (external demand signal)
5.3.5 Intermittent Control of Emission and/or Distribution
5.3.5.1 Type 1 – Automatic Control with fixed Time Program
57 5.3.5.2 Type 2 – Automatic control with Optimum Start/Stop
59 5.3.5.3 Type 3 – Automatic control with demand evaluation
60 5.3.6 Interlock between heating and cooling control of emission and/or distribution
5.3.6.1 Type 1 – Partial interlock
5.3.6.2 Type 2 – Total interlock
61 5.3.7 Generator control for cooling
5.3.7.1 Type 1 – Variable temperature control depending on outside temperature
5.3.7.2 Type 2 – Variable temperature control depending on the load
62 5.3.8 Sequencing of different chillers (generators for chilled water)
5.3.8.1 Type 1 – Fixed sequencing based on loads only
63 5.3.8.2 Type 2 – Priorities based on generator efficiency and characteristics
5.3.8.3 Type 3 – Load prediction based sequencing
64 5.3.9 Control of Thermal Energy Storage (TES) charging
5.3.9.1 Type 1 – Time scheduled storage operation
5.3.9.2 Type 2 – Load prediction based storage operation
65 5.3.10 Hydronic balancing cooling distribution (including contribution to balancing to the emission side)
5.3.10.1 Type 1 – Balanced statically per emitter, without group balance
66 5.3.10.2 Type 2 – Balanced statically per emitter, and a static group balance
5.3.10.3 Type 3 – Balanced statically per emitter and dynamic group balance
67 5.3.10.4 Type 4 – Balanced dynamically per emitter
68 5.4 Ventilation and air conditioning control
5.4.1 Supply air flow control at the room level
5.4.1.1 Type 1 – Time control
5.4.1.2 Type 2 – Occupancy based control
69 5.4.1.3 Type 3 – Demand based control
70 5.4.2 Room air temperature control by the ventilation system (all-air systems; combination with static systems as cooling ceiling, radiators etc.)
5.4.2.1 Type 1 – Continuous control
71 5.4.2.2 Type 2 – Optimized control
72 5.4.3 Coordination of room air temperature control by ventilation and by static systems
5.4.4 Outside air flow control
5.4.4.1 Type 1 – Staged (low or high) outside air ratio/outside air flow: depending on a given time schedule
73 5.4.4.2 Type 2 – Staged (low or high) outside air ratio/outside air flow: depending on the occupancy
5.4.4.3 Type 3 – Variable control
74 5.4.5 Air flow or pressure control at the air handler level
5.4.5.1 Type 1 – On/off time control
5.4.5.2 Type 2 – Multi-stage control
75 5.4.5.3 Type 3 – Automatic flow or pressure control without pressure reset
76 5.4.5.4 Type 4 – Automatic flow or pressure control with pressure reset
77 5.4.6 Heat recovery control (icing protection)
5.4.6.1 Type 1 – With icing protection control
78 5.4.7 Heat recovery control (prevention of overheating)
5.4.7.1 Type 1 – With overheating control
79 5.4.8 Free mechanical cooling
5.4.8.1 Type 1 – Night cooling
5.4.8.2 Type 2 – Free cooling
80 5.4.8.3 Type 3 – H,x-directed control
81 5.4.9 Supply air temperature control at the air handling unit level
5.4.9.1 Type 1 – Constant setpoint
5.4.9.2 Type 2 – Variable setpoint with OTC
82 5.4.9.3 Type 3 – Variable setpoint with load dependant compensation
5.4.10 Humidity control
5.4.10.1 Type 1 – Dew point control
83 5.4.10.2 Type 2 – Direct humidity control
5.5 Lighting control
5.5.1 Occupancy control
5.5.1.1 Type 1 – Manual on/off switch plus additional sweeping extinction signal
84 5.5.1.2 Type 2 – Automatic detection
85 5.5.1.3 Type 3 – Automatic detection – switch or dim off
86 5.5.2 Light level/Daylight control (daylight harvesting)
5.5.2.1 Type 1 – Manual switching off of luminaires
87 5.5.2.2 Type 2 – Automatic switching daylight control
5.5.2.3 Type 3 – Automatic dimming daylight control
88 5.6 Blind control
5.6.1 Type 1 – Motorized operation of blind with manual control
89 5.6.2 Type 2 – Motorized operation of blind with automatic control
91 5.6.3 Type 3 – Combined light/blind/HVAC control
92 6 Functional elements
6.1 Sensor Functions
6.1.1 Air quality measurement
93 6.1.2 Air temperature measurement
94 6.1.3 Dewpoint monitoring
95 6.1.4 Humidity measurement
96 6.1.5 Brightness measurement
97 6.1.6 Precipitation detection
98 6.1.7 Presence detection
99 6.1.8 Window monitoring
100 6.1.9 Wind speed measurement
101 6.2 Actuator Functions
6.2.1 Solar protection actuator
103 6.2.2 Drive Actuator
104 6.2.3 Lighting Actuator
105 6.3 Display and User Operation Functions
6.3.1 Operate Lighting
106 6.3.2 Operate Solar Protection
107 6.3.3 Operate Drive
108 6.3.4 Set Temperature setpoint
109 6.3.5 Display Current Temperature
110 6.3.6 Select room utilisation type
111 6.3.7 Set presence
112 6.4 Control Functions
6.4.1 Presence Evaluation
113 6.4.2 Predefined operation setting (scenario)
114 6.4.3 Schedule
116 6.4.4 Manual Lighting Control
117 6.4.5 Timed Lighting Control
118 6.4.6 Partition wall control
119 6.4.7 Occupancy dependent lighting control
120 6.4.8 Daylight-dependent lighting
122 6.4.9 Constant-light control
124 6.4.10 Twilight control
125 6.4.11 Priority control
127 6.4.12 Automatic twilight control
129 6.4.13 Automatic solar control (simple solar protection)
130 6.4.14 Slat tracking (complex solar protection)
132 6.4.15 Shadow correction
134 6.4.16 Automatic thermal control
135 6.4.17 Weather protection
137 6.4.18 Energy mode selection
139 6.4.19 Energy mode selection with start optimisation
141 6.4.20 Setpoint calculation
143 6.4.21 Function selection
145 6.4.22 Temperature control (heating/cooling)
147 6.4.23 Room supply air temperature cascade control
149 6.4.24 Fan control
151 6.4.25 Sequence control
152 6.4.26 Control value limiting
153 6.4.27 Air quality control
155 6.4.28 Night-time cooling
156 6.4.29 Volume flow control
BS EN 17609:2022