BS EN 17609:2022:2023 Edition
$215.11
Building automation and control systems. Control applications
Published By | Publication Date | Number of Pages |
BSI | 2023 | 160 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
12 | 1 Scope 2 Normative references 3 Terms and definitions |
14 | 4 Abbreviations |
16 | 5 Functional specifications having an impact on energy performance, comfort, and operational requirements of buildings 5.1 Heating control 5.1.1 Emission control 5.1.1.1 Type 1 – Central automatic control |
17 | 5.1.1.2 Type 2 – Individual room control |
18 | 5.1.1.3 Type 3 – Individual modulating room control with communication |
19 | 5.1.1.4 Type 4 – Individual modulating room control with communication and occupancy detection |
20 | 5.1.2 Emission control for TABS (heating mode) 5.1.2.1 Type 1 – Central automatic control 5.1.2.2 Type 2 – Advanced central automatic control |
21 | 5.1.2.3 Type 3 – Advanced central automatic control with intermittent operation and/or room temperature feedback control |
23 | 5.1.3 Control of distribution network hot water temperature (supply or return) 5.1.3.1 Type 1 – Outside air temperature compensated control 5.1.3.2 Type 2 – Demand based control |
24 | 5.1.4 Control of distribution pumps in networks 5.1.4.1 Type 1 – On/Off control |
25 | 5.1.4.2 Type 2 – Multi stage control |
26 | 5.1.4.3 Type 3 – Variable speed pump control (pump unit (internal) estimations) |
27 | 5.1.4.4 Type 4 – Variable speed pump control (external demand signal) 5.1.5 Intermittent control of emission and/or distribution 5.1.5.1 Type 1 – Automatic Control with fixed Time Program |
29 | 5.1.5.2 Type 2 – Automatic control with Optimum Start/Stop |
30 | 5.1.5.3 Type 3 – Automatic control with demand evaluation |
31 | 5.1.6 Heat generator control (combustion and district heating) 5.1.6.1 Type 1 – Variable temperature control depending on outside temperature 5.1.6.2 Type 2 – Variable temperature control depending on the load |
32 | 5.1.7 Heat generator control (heat pump) 5.1.7.1 Type 1 -Variable temperature depending on outdoor temperature |
33 | 5.1.7.2 Type 2 – Variable temperature depending on the load |
34 | 5.1.8 Heat generator control (outdoor unit) 5.1.8.1 Type 1 -Multi-stage control of heat generator depending on the load or demand 5.1.8.2 Type 2 -Variable control of heat generator capacity depending on the load or demand |
35 | 5.1.9 Sequencing of different heat generators 5.1.9.1 Type 1 – Control according to fixed priority list |
36 | 5.1.9.2 Type 2 – Control according to dynamic priority list based on generator efficiency and capacity |
37 | 5.1.9.3 Type 3 – Control according to dynamic priority list based on predicted and current load, efficiency and capacity of generators 5.1.10 Control of Thermal Energy Storage (TES) charging 5.1.10.1 Type 1 – 2-sensor charging of storage |
38 | 5.1.10.2 Type 2 – Load prediction based storage operation 5.1.11 Hydronic balancing heating distribution (including contribution to balancing to the emission side) 5.1.11.1 Type 1 – Balanced statically per emitter, without group balance |
39 | 5.1.11.2 Type 2 – Balanced statically per emitter, and a static group balance |
40 | 5.1.11.3 Type 3 – Balanced statically per emitter and dynamic group balance 5.1.11.4 Type 4 – Balanced dynamically per emitter |
41 | 5.2 Domestic hot water supply control 5.2.1 Control of DHW storage charging with direct electric heating or integrated electric heat pump 5.2.1.1 Type 1 – Automatic control on/off and scheduled charging enable |
42 | 5.2.1.2 Type 2 – Automatic on/off control and scheduled charging enable and multi-sensor storage management 5.2.2 Control of DHW storage charging using hot water generation 5.2.2.1 Type 1 – Automatic on/off control and scheduled charging enable |
43 | 5.2.2.2 Type 2 – Automatic on/off control and scheduled charging enable and demand-based supply temperature control or multi-sensor storage management |
44 | 5.2.3 Control of DHW storage charging with solar collector and supplementary heat generation 5.2.3.1 Type 1 – Automatic control of solar storage charge (Prio. 1) and supplementary storage charge (Prio. 2) |
45 | 5.2.3.2 Type 2 – Automatic control of solar storage charge (Prio. 1) and supplementary storage charge (Prio. 2) plus demand based supply temperature control or multi-sensor storage management |
46 | 5.2.4 Control of DHW circulation pump 5.2.4.1 Type 1 – Control of DHW circulation pump, with time switch program |
47 | 5.3 Cooling control 5.3.1 Emission Control 5.3.1.1 Type 1 – Central automatic control |
48 | 5.3.1.2 Type 2 – Individual room control 5.3.1.3 Type 3 – Individual modulating room control with communication |
49 | 5.3.1.4 Type 4 – Individual modulating room control with communication and occupancy detection |
50 | 5.3.2 Emission control for TABS (cooling mode) 5.3.2.1 Type 1 – Central automatic control |
51 | 5.3.2.2 Type 2 – Advanced central automatic control |
52 | 5.3.2.3 Type 3 – Advanced central automatic control with intermittent operation and/or room temperature feedback control |
53 | 5.3.3 Control of distribution network chilled water temperature (supply or return) 5.3.3.1 Type 1 – Outside temperature compensated control 5.3.3.2 Type 2 – Demand based control |
54 | 5.3.4 Control of distribution pumps in hydraulic networks 5.3.4.1 Type 1 – On/Off control |
55 | 5.3.4.2 Type 2 – Multi-stage control 5.3.4.3 Type 3 – Variable speed pump control (pump unit (internal) estimations) |
56 | 5.3.4.4 Type 4 – Variable speed pump control (external demand signal) 5.3.5 Intermittent Control of Emission and/or Distribution 5.3.5.1 Type 1 – Automatic Control with fixed Time Program |
57 | 5.3.5.2 Type 2 – Automatic control with Optimum Start/Stop |
59 | 5.3.5.3 Type 3 – Automatic control with demand evaluation |
60 | 5.3.6 Interlock between heating and cooling control of emission and/or distribution 5.3.6.1 Type 1 – Partial interlock 5.3.6.2 Type 2 – Total interlock |
61 | 5.3.7 Generator control for cooling 5.3.7.1 Type 1 – Variable temperature control depending on outside temperature 5.3.7.2 Type 2 – Variable temperature control depending on the load |
62 | 5.3.8 Sequencing of different chillers (generators for chilled water) 5.3.8.1 Type 1 – Fixed sequencing based on loads only |
63 | 5.3.8.2 Type 2 – Priorities based on generator efficiency and characteristics 5.3.8.3 Type 3 – Load prediction based sequencing |
64 | 5.3.9 Control of Thermal Energy Storage (TES) charging 5.3.9.1 Type 1 – Time scheduled storage operation 5.3.9.2 Type 2 – Load prediction based storage operation |
65 | 5.3.10 Hydronic balancing cooling distribution (including contribution to balancing to the emission side) 5.3.10.1 Type 1 – Balanced statically per emitter, without group balance |
66 | 5.3.10.2 Type 2 – Balanced statically per emitter, and a static group balance 5.3.10.3 Type 3 – Balanced statically per emitter and dynamic group balance |
67 | 5.3.10.4 Type 4 – Balanced dynamically per emitter |
68 | 5.4 Ventilation and air conditioning control 5.4.1 Supply air flow control at the room level 5.4.1.1 Type 1 – Time control 5.4.1.2 Type 2 – Occupancy based control |
69 | 5.4.1.3 Type 3 – Demand based control |
70 | 5.4.2 Room air temperature control by the ventilation system (all-air systems; combination with static systems as cooling ceiling, radiators etc.) 5.4.2.1 Type 1 – Continuous control |
71 | 5.4.2.2 Type 2 – Optimized control |
72 | 5.4.3 Coordination of room air temperature control by ventilation and by static systems 5.4.4 Outside air flow control 5.4.4.1 Type 1 – Staged (low or high) outside air ratio/outside air flow: depending on a given time schedule |
73 | 5.4.4.2 Type 2 – Staged (low or high) outside air ratio/outside air flow: depending on the occupancy 5.4.4.3 Type 3 – Variable control |
74 | 5.4.5 Air flow or pressure control at the air handler level 5.4.5.1 Type 1 – On/off time control 5.4.5.2 Type 2 – Multi-stage control |
75 | 5.4.5.3 Type 3 – Automatic flow or pressure control without pressure reset |
76 | 5.4.5.4 Type 4 – Automatic flow or pressure control with pressure reset |
77 | 5.4.6 Heat recovery control (icing protection) 5.4.6.1 Type 1 – With icing protection control |
78 | 5.4.7 Heat recovery control (prevention of overheating) 5.4.7.1 Type 1 – With overheating control |
79 | 5.4.8 Free mechanical cooling 5.4.8.1 Type 1 – Night cooling 5.4.8.2 Type 2 – Free cooling |
80 | 5.4.8.3 Type 3 – H,x-directed control |
81 | 5.4.9 Supply air temperature control at the air handling unit level 5.4.9.1 Type 1 – Constant setpoint 5.4.9.2 Type 2 – Variable setpoint with OTC |
82 | 5.4.9.3 Type 3 – Variable setpoint with load dependant compensation 5.4.10 Humidity control 5.4.10.1 Type 1 – Dew point control |
83 | 5.4.10.2 Type 2 – Direct humidity control 5.5 Lighting control 5.5.1 Occupancy control 5.5.1.1 Type 1 – Manual on/off switch plus additional sweeping extinction signal |
84 | 5.5.1.2 Type 2 – Automatic detection |
85 | 5.5.1.3 Type 3 – Automatic detection – switch or dim off |
86 | 5.5.2 Light level/Daylight control (daylight harvesting) 5.5.2.1 Type 1 – Manual switching off of luminaires |
87 | 5.5.2.2 Type 2 – Automatic switching daylight control 5.5.2.3 Type 3 – Automatic dimming daylight control |
88 | 5.6 Blind control 5.6.1 Type 1 – Motorized operation of blind with manual control |
89 | 5.6.2 Type 2 – Motorized operation of blind with automatic control |
91 | 5.6.3 Type 3 – Combined light/blind/HVAC control |
92 | 6 Functional elements 6.1 Sensor Functions 6.1.1 Air quality measurement |
93 | 6.1.2 Air temperature measurement |
94 | 6.1.3 Dewpoint monitoring |
95 | 6.1.4 Humidity measurement |
96 | 6.1.5 Brightness measurement |
97 | 6.1.6 Precipitation detection |
98 | 6.1.7 Presence detection |
99 | 6.1.8 Window monitoring |
100 | 6.1.9 Wind speed measurement |
101 | 6.2 Actuator Functions 6.2.1 Solar protection actuator |
103 | 6.2.2 Drive Actuator |
104 | 6.2.3 Lighting Actuator |
105 | 6.3 Display and User Operation Functions 6.3.1 Operate Lighting |
106 | 6.3.2 Operate Solar Protection |
107 | 6.3.3 Operate Drive |
108 | 6.3.4 Set Temperature setpoint |
109 | 6.3.5 Display Current Temperature |
110 | 6.3.6 Select room utilisation type |
111 | 6.3.7 Set presence |
112 | 6.4 Control Functions 6.4.1 Presence Evaluation |
113 | 6.4.2 Predefined operation setting (scenario) |
114 | 6.4.3 Schedule |
116 | 6.4.4 Manual Lighting Control |
117 | 6.4.5 Timed Lighting Control |
118 | 6.4.6 Partition wall control |
119 | 6.4.7 Occupancy dependent lighting control |
120 | 6.4.8 Daylight-dependent lighting |
122 | 6.4.9 Constant-light control |
124 | 6.4.10 Twilight control |
125 | 6.4.11 Priority control |
127 | 6.4.12 Automatic twilight control |
129 | 6.4.13 Automatic solar control (simple solar protection) |
130 | 6.4.14 Slat tracking (complex solar protection) |
132 | 6.4.15 Shadow correction |
134 | 6.4.16 Automatic thermal control |
135 | 6.4.17 Weather protection |
137 | 6.4.18 Energy mode selection |
139 | 6.4.19 Energy mode selection with start optimisation |
141 | 6.4.20 Setpoint calculation |
143 | 6.4.21 Function selection |
145 | 6.4.22 Temperature control (heating/cooling) |
147 | 6.4.23 Room supply air temperature cascade control |
149 | 6.4.24 Fan control |
151 | 6.4.25 Sequence control |
152 | 6.4.26 Control value limiting |
153 | 6.4.27 Air quality control |
155 | 6.4.28 Night-time cooling |
156 | 6.4.29 Volume flow control |