BS EN 15609:2021:2022 Edition
$189.07
LPG equipment and accessories. LPG propulsion systems for boats, yachts and other watercraft. Installation requirements
Published By | Publication Date | Number of Pages |
BSI | 2022 | 50 |
This document specifies the installation requirements for LPG propulsion systems on watercraft with hull lengths less than or equal to 24 m, as defined in EN ISO 8666 [11]. This document does not cover appliances with directly attached gas cylinders, such as portable self-contained camping stoves and portable gas lamps.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
10 | 1 Scope 2 Normative references |
11 | 3 Terms and definitions |
15 | 4 Components 4.1 Overview 4.2 LPG containers/cylinders 4.2.1 General 4.2.2 Cylinders |
16 | 4.2.3 Fixed container 4.2.3.1 General 4.2.3.2 Components fitted to the fixed container |
17 | 4.3 Fuel system components 4.3.1 Pressure regulator/vaporizer 4.3.2 Other components 5 Installation requirements 5.1 General requirements |
18 | 5.2 Installer of a permanently installed LPG system |
19 | 5.3 Additional LPG systems 5.4 Modifications to the structure of the watercraft 5.5 LPG container/cylinder installation 5.5.1 General |
20 | 5.5.2 Fixed containers 5.5.3 Cylinders |
21 | 5.5.4 Container lockers 5.5.5 Installation of more than one container/cylinder |
22 | 5.6 Components fitted to the fixed container 5.6.1 General requirements 5.6.2 Remote-controlled service valve with excess flow valve on the fixed container 5.6.3 Pressure relief valve 5.6.4 Fusible plug 5.6.5 Filler valve 5.6.6 Overfill protection device 5.6.7 Level indicator 5.6.8 Fittings 5.7 Gas pipes and hoses |
23 | 5.8 Other components 5.8.1 Gas connections between components of the LPG-system |
25 | 5.8.2 Remote-controlled shut-off valve 5.8.2.1 Fixed container − liquid phase pressure regulator/vaporizer fuel system 5.8.2.2 Fixed container – liquid phase for liquid LPG injection fuel system 5.8.2.3 Cylinders — liquid phase 5.8.3 Filling unit |
26 | 5.9 Electrical installation |
27 | 5.10 Bi-fuel and dual-fuel systems 5.11 Gas detection 5.11.1 General 5.11.2 Alarm position |
28 | 5.11.3 Sensors position 5.12 Powered ventilation 5.12.1 General 5.12.2 Purging of engine and/or LPG container/cylinder space 6 Fire-extinguishing equipment 7 Owner’s manual 8 Commissioning 8.1 Tightness test – fixed containers |
29 | 8.2 Initial filling of the container and the system with LPG 8.3 LPG system test 8.4 Water trial |
30 | Annex A (normative)Fixing requirements for containers/cylinders A.1 General requirements |
31 | A.2 Container frame |
32 | Annex B (normative)Cylinder securing requirements B.1 Removable LPG cylinders B.2 Permanently installed LPG cylinders B.3 LPG cylinders more than 16 kg |
35 | Annex C (normative)Instructions to be included in the owner’s manual C.1 General requirements C.2 Availability of LPG supply C.3 Position and operation of emergency shut-off valve C.4 Safety instructions to be included in the manual |
36 | C.5 Instruction for the normal use of the LPG system C.5.1 Filling of the LPG system C.5.2 Switching procedure (for bi-fuelled watercraft) C.5.3 Opening and closing of manual valves (in the case of multiple containers) C.5.4 Liquid level indicator C.5.5 Maintenance and inspection |
37 | C.5.6 Defects and repairs C.5.7 Storage, repair and maintenance C.5.8 Disposal |
38 | C.5.9 Hot work |
39 | Annex D (normative)Additional test requirements for vaporizers |
41 | Annex E (informative)Installation of more than one container |
43 | Annex F (informative)Example of installation certificate |
44 | Annex G (informative)Types of LPG Propulsion systems G.1 Hybrid electric LPG propulsion G.1.1 General G.1.2 LPG /electric propulsion |
45 | G.1.3 Serial hybrid LPG/electric propulsion G.1.4 Parallel hybrid LPG/electrical propulsion |
47 | Annex ZA (informative)Relationship between this European Standard and the essential requirements of Directive 2013/53/EU aimed to be covered |