BS EN 15316-2:2017
$198.66
Energy performance of buildings. Method for calculation of system energy requirements and system efficiencies – Space emission systems (heating and cooling), Module M3-5, M4-5
Published By | Publication Date | Number of Pages |
BSI | 2017 | 58 |
This European Standard’s scope is to standardize the required inputs, the outputs and the links (structure) of the calculation method in order to achieve a common European calculation method. This standard covers energy performance calculation of heating systems and water based cooling space emission sub-systems. Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in prEN ISO 52000 1. NOTE 1 In prCEN ISO/TR 52000 2, the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation. NOTE 2 The modules represent EPB standards, although one EPB standard may cover more than one module and one module may be covered by more than one EPB standard, for instance a simplified and a detailed method respectively. See also Clause 2 and Tables A.1 and B.1.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
9 | 1 Scope |
11 | 2 Normative references 3 Terms and definitions |
12 | 4 Symbols and abbreviations 5 Description of the method |
13 | 6 Calculation Method |
26 | 7 Quality control 8 Compliance check |
27 | Annex A (normative)Template for choices, input data and references (Additional heating and cooling losses / auxiliary energy) A.1 Introduction |
28 | A.2 Temperature variation for free heating surfaces (radiators), room heights ≤ 4 m (heating case) |
30 | A.3 Temperature Variation for component integrated heating surfaces (panel heaters) (room heights ≤ 4 m, heating case) |
32 | A.4 Temperature variation for air heating systems; room heights ≤ 4 m (heating case) |
33 | A.5 Temperature Variation for electrical heating and air heating (room heights ≤ 4 m, heating case) |
34 | A.6 Temperature Variation air heating (ventilation systems, room heights ≤ 4 m, heating case) A.7 Temperature variation for room spaces with heights > 4 m (large indoor space buildings, heating case) |
37 | A.8 Temperature variation for room heaters fired by solid fuel |
38 | A.9 Temperature variation for water based cooling systems; room heights ≤ 4 m (cooling case) |
39 | A.10 Auxiliary Energy |
40 | A.11 Additional Information |
42 | Annex B (informative)Default choices, input data and references (additional heating and cooling losses / auxiliary energy) B.1 Introduction |
43 | B.2 Temperature variation for free heating surfaces (radiators); room heights ≤ 4 m (heating case) |
45 | B.3 Temperature Variation for component integrated heating surfaces (panel heaters) (room heights ≤ 4 m, heating case) |
47 | B.4 Temperature variation for air heating systems; room heights ≤ 4 m (heating case) |
48 | B.5 Temperature Variation for electrical heating and air heating (room heights ≤ 4 m, heating case) |
49 | B.6 Temperature Variation air heating (ventilation systems, room heights ≤ 4 m, heating case) B.7 Temperature variation for room spaces with heights > 4 m (large indoor space buildings, heating case) |
52 | B.8 Temperature variation for room heaters fired by solid fuel |
53 | B.9 Temperature variation for water based cooling systems; room heights ≤ 4 m (cooling case) |
54 | B.10 Auxiliary Energy |
55 | B.11 Additional Information |