Historical Standard: Standard Test Method for On-Line Determination of Anions and Carbon Dioxide in High Purity Water by Cation Exchange and Degassed Cation Conductivity

ASTM D4519

Scope

1.1 This on-line test method includes hydrogen exchange and degassing by boiling and provides means for determining anions (such as Cl , SO4, NO 3, and F ) at levels as low as 2 μg/L (2 ppb) and carbon dioxide at the level of 0.01 to 10 mg/L (ppm) at 25°C in high purity water and steam condensate by measuring electrical conductivity.

1.2 The conductivity of all anions (except OH ) is determined and not the conductivity of an individual anion if more than one is present. If only one anion is present (such as Cl or SO4 ), reference to Table 1 and Table 2 or Figs. 1-3 provides the chloride or sulfate and CO2 concentration.

1.3 This test method has been improved in accuracy by using a modern microprocessor instrument for conductivity and temperature measurement and appropriate temperature compensation algorithms for compensation to 25°C.

1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

anion electrical conductivity; carbon dioxide; cation conductivity; degassed cation conductivity; electrical conductivity; high purity water; reboiled conductivity; Water quality monitoring; Anion electrical conductivity; Automated procedures–water analysis; Carbon dioxide content; Cation conductivity; Conductance and conductivity (electrical)–water; De-gassed cation conductivity; High-pressure power plants; High-purity water; Hydrogen ion exchange; Impurities–water; Microelectronic device processing–water; Reagent water; Reboiled conductivity; Steam

ICS Code

ICS Number Code 17.220.20 (Measurement of electrical and magnetic quantities)

DOI: 10.1520/D4519-10

PDF Catalog

PDF Pages PDF Title
1 Scope
Referenced Documents
Terminology
Summary of Test Method
TABLE 1
2 Significance and Use
Interferences
TABLE 2
FIG. 1
3 Apparatus
Reagents
FIG. 2
FIG. 3
4 Sampling
Calibration
Procedure
Report
Precision and Bias
Keywords
5 FIG. 4
6 A1. EFFECTS OF THE INFLUENT WATER TEMPERATURE
A1.1
FIG. 5
7 A2. EFFECTS OF SAMPLE VELOCITY
A2.1
A3. TEMPERATURE COMPENSATION OF THE INSTRUMENT
A3.1
FIG. A1.1
FIG. A2.1
8 A4. ORGANIC ACIDS
A4.1
ASTM-D4519