ASME B31Q 2006

$98.04

ASME B31Q Pipeline Personnel Qualification

Published By Publication Date Number of Pages
ASME 2006 190
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
4 TABLE OF CONTENTS
15 FOREWORD
18 COMMITTEE ROSTER
22 1 INTRODUCTION
1.1 Scope
1.2 Purpose and Objectives
24 2 DEFINITIONS
26 3 REFERENCES
28 4 QUALIFICATION PROGRAM
4.1 Development
4.2 Processes and Procedures
4.2.1 Introduction
4.2.2 Definitions (See Section 2)
4.2.3 Determining Covered Tasks (See Section 5)
4.2.4 Abnormal Operating Conditions (AOCs) (See Section 6)
29 4.2.5 Training (See Section 7)
4.2.6 Evaluations (See Section 8)
4.2.7 Qualifications (See Section 9)
4.2.8 Portability of Evaluations (See Section 10)
4.2.9 Program Effectiveness (See Section 11)
30 4.2.10 Communication of Program Requirements and Change (See Section 12)
4.2.11 Documentation (See Section 13)
32 5 DETERMINING COVERED TASKS
5.1 Introduction
5.2 Processes for Determining Covered Tasks
5.3 SME Covered Task Identification Process
5.3.1 Selecting SMEs
33 5.3.2 Identifying Covered Tasks
5.4 Fault Tree Task Identification Process
34 5.5 Using the Task List in Appendix 5A
38 6 ABNORMAL OPERATING CONDITIONS (AOCS)
40 7 TRAINING
7.1 Responsibility
7.1.1 Employers
7.1.2 Qualification Program
7.2 Identification of the Need for Training an Individual
7.2.1 Determining Training Needs
7.2.2 Situations for Considering Training
41 7.3 Training Materials and Implementation
7.3.1 Training Materials
7.3.2 Training Implementation
7.3.3 Training Tests
7.4 Training Documentation
7.4.1 Documenting Training Needs
7.4.2 Documenting Training
42 8 EVALUATION
8.1 Evaluation Process
8.1.1 Responsibilities
8.1.2 Procedures
43 8.2 Evaluation Material(s) and Criteria
8.2.1 Content Validity
8.2.2 Evaluation Criteria
44 8.2.3 Evaluation Method Selection
8.3 Method-Specific Evaluation Requirements
8.3.1 Written Evaluations
8.3.2 Oral Interview Evaluations
45 8.3.3 Performance Evaluations
46 9 QUALIFICATIONS
9.1 Qualification Requirements
9.1.1 Responsibilities
47 9.1.2 Other Codes or Standards
9.1.3 Qualification Process
48 9.2 Suspension and Revocation of Qualification
9.2.1 Suspension
9.2.2 Reinstatement
9.2.3 Revocation
9.2.4 Additional Qualification
49 9.3 Qualification Requirements for Emergency Response
9.4 Performance of Covered Tasks by Non-Qualified Individuals
9.4.1 Direct and Observe
9.4.2 Span of Control Ratio Development and Maintenance
50 9.5 Subsequent Qualification Interval
9.5.1 Development and Implementation
51 9.5.2 Methods
9.5.3 SME Consensus
9.5.4 Difficulty and Importance Analysis; or Difficulty, Importance and Frequency Analysis
9.5.5 Adoption of Appendix 5A Subsequent Qualification Intervals
52 10 PORTABILITY
10.1 Evaluation Portability Requirements
10.1.1 Section 2 Definitions
10.1.2 Section 3 References and Standards
10.1.3 Section 5 Determining Covered Tasks
10.1.4 Section 6 Abnormal Operating Conditions ( AOCs)
10.1.5 Section 8 Evaluation
53 10.1.6 Section 9 Qualifications
10.1.7 Section 12 Communicating the Qualification Program and Managing Program Changes
10.1.8 Section 13 Documentation Requirements
54 11 PROGRAM EFFECTIVENESS
11.1 General
56 12 COMMUNICATING THE QUALIFICATION PROGRAM AND MANAGING PROGRAM CHANGES
12.1 Communicating the Qualification Program
12.1.1 Program Requirements
12.1.2 Qualified Individuals
12.1.3 Program Responsibilities
57 12.2 Managing Program Changes
12.2.1 Management of Change Process
12.2.2 Conditions for Change
58 12.2.3 Rating the Impact of Changes
60 13 DOCUMENTATION REQUIREMENTS
13.1 Documenting the Qualification Program (Section 4)
13.2 Documenting Communication of the Qualification Program (Section 12)
13.3 Documenting Identification of Covered Tasks (Sections 5, 8, and 9)
13.3.1 Process for Identifying Covered Tasks
13.3.2 Covered Task List
13.3.3 Evaluation Criteria
13.3.4 Evaluation Method
13.3.5 Subsequent Qualification Interval
13.3.6 Span of Control
13.4 Documenting Abnormal Operating Conditions ( AOCs) ( Section 6)
13.5 Documenting Training Needs ( Section 7)
61 13.6 Documenting Training
13.7 Documenting an Individual’s Qualification
13.7.1 Qualified Individual
13.7.2 Covered Task
13.7.3 AOCs
13.7.4 Evaluation Method
13.7.5 Qualification Date
13.7.6 Testing
13.7.7 Evaluator
13.8 Documenting Credentials of an Evaluator ( Section 8)
13.9 Documenting Program Changes ( Section 12)
62 13.10 Documenting Program Effectiveness Appraisals ( Section 11)
13.11 Maintenance of Documents
13.11.1 Formatting
13.11.2 Record Life
64 14 BIBLIOGRAPHY
66 NONMANDATORY APPENDIX 5A – INTEGRATED TASK LIST
67 Task 0001 Measure Structure- To- Electrolyte Potential
Task 0011 Conduct Close Interval Survey
Task 0021 Measure Soil Resistivity
68 Task 0031 Inspect And Monitor Galvanic Ground Beds/ Anodes
Task 0041 Installation And Maintenance of Mechanical Electrical Connections
69 Task 0051 Installation of Exothermic Electrical Connections
Task 0061 Inspect or Test Cathodic Protection Bonds
70 Task 0071 Inspect or Test Cathodic Protection Electrical Isolation Devices
Task 0081 Install Cathodic Protection Electrical Isolation Devices
Task 0091 Troubleshoot in- Service Cathodic Protection System
71 Task 0101 Inspect Rectifier And Obtain Readings
Task 0111 Maintain Rectifier
72 Task 0121 Collect Sample For Internal Corrosion Monitoring
Task 0131 Insert And Remove Coupons/ Probes For Internal Corrosion Monitoring
73 Task 0141 Visual Inspection For Atmospheric Corrosion
Task 0151 Visual Inspection of Buried Pipe and Components When Exposed
Task 0161 Visual Inspection for Internal Corrosion
74 Task 0171 Measure External Corrosion
Task 0181 Measure Internal Corrosion
75 Task 0191 Measure Atmospheric Corrosion
Task 0201 Visual Inspection of Installed Pipe and Components for Mechanical Damage
76 Task 0211 Measure and Characterize Mechanical Damage on Installed Pipe and Components
Task 0221 Inspect, Test and Maintain Sensing Devices
77 Task 0231 Inspect, Test and Maintain Programmable Logic Controllers
Task 0241 Inspect, Test and Maintain Liquid Leak Detection Flow Computers
78 Task 0251 Inspection and Testing, Corrective and Preventive Maintenance – Overfill Protection Systems
79 Task 0261 Inspection, Testing, Corrective and Preventive Maintenance – Tank Gauges for Leak Detection
Task 0271 Prove Flow Meters for Hazardous Liquid Leak Detection
80 Task 0281 Maintain Flow Meters for Hazardous Liquid Leak Detection
Task 0291 Inspect, Test and Maintain Gravitometers/ Densitometers for Hazardous Liquid Leak Detection
81 Task 0301 Manually Opening and Closing Valves
Task 0311 Adjust and Monitor Flow or Pressure – Manual Valve Operation
82 Task 0321 Valve Corrective Maintenance
83 Task 0331 Valve – Visual Inspection and Partial Operation
Task 0341 Valve – Preventive Maintenance
84 Task 0351 Pneumatic Actuator/ Operator Inspection and Testing, Preventive and Corrective Maintenance
Task 0361 Electric Actuator/ Operator Inspection and Testing, Preventive and Corrective Maintenance
85 Task 0371 Hydraulic Actuator/ Operator Inspection and Testing, Preventive and Corrective Maintenance
Task 0381 Spring Loaded Pressure Regulating Device – Inspection and Testing, Preventive and Corrective Maintenance
86 Task 0391 Pilot – Operated Pressure Regulating Device – Inspection, Testing, Preventive and Corrective Maintenance
87 Task 0401 Controller Type Pressure Regulating Device – Inspection, Testing, Preventive and Corrective Maintenance
88 Task 0411 Spring – Loaded Pressure Limiting and Relief Device – Inspection, Testing, Preventive and Corrective Maintenance
Task 0421 Pilot Operated Pressure Limiting and Relief Device – Inspection, Testing, Preventive and Corrective Maintenance
89 Task 0431 Pneumatic Loaded Pressure Limiting and Relief Device – Inspection, Testing, Preventive and Corrective Maintenance
90 Task 0441 Compressor Start- Up and Shutdown – Manual
Task 0451 Pump – Start- Up and Shutdown – Manual
91 Task 0461 Compressor Preventive Maintenance
Task 0471 Reciprocating Compressor Inspection, Testing and Corrective Maintenance
92 Task 0481 Centrifugal Compressor Inspection, Testing and Corrective Maintenance
Task 0491 Rotary Compressor Inspection, Testing and Corrective Maintenance
93 Task 0501 Pump Preventive Maintenance
Task 0511 Centrifugal Pump Inspection, Testing and Corrective Maintenance
94 Task 0521 Reciprocating Pump Inspection, Testing and Corrective Maintenance
Task 0531 Rotary Pump Inspection, Testing and Corrective Maintenance
95 Task 0541 Screw Pump Inspection, Testing and Corrective Maintenance
Task 0551 Explosive Atmosphere Detection and Alarm System Performance Test, and Corrective Maintenance
96 Task 0561 Pressure Test – Nonliquid Medium – MAOP Less Than 100 Psi
Task 0571 Pressure Test – Nonliquid Medium – MAOP Greater Than or Equal to 100 Psi
97 Task 0581 Pressure Test – Liquid Medium
Task 0591 Leak Test at Operating Pressure
98 Task 0601 NDT – Radiographic Testing
Task 0611 NDT – Liquid Penetrant Testing
Task 0621 NDT – Magnetic Particle Testing
99 Task 0631 NDT – Ultrasonic Testing
Task 0641 Visually Inspect Pipe and Components Prior To Installation
100 Task 0651 Routine Visual Inspection of Breakout Tanks
Task 0661 Inspection of Breakout Tanks
Task 0671 Joining of Plastic Pipe – Solvent Cement
101 Task 0681 Joining of Plastic Pipe – Stab Fittings
Task 0691 Joining of Pipe – Non- Bottom Out Compression Couplings
102 Task 0701 Joining of Pipe – Bottom Out Compression Couplings
Task 0711 Joining of Pipe – Compression Couplings
103 Task 0721 Joining of Pipe – Threaded Joints
Task 0731 Joining of Pipe — Flange Assembly
104 Task 0741 Joining of Pipe – Brazing or Soldering
Task 0751 Joining of Plastic Pipe – Butt Heat Fusion: Manual
105 Task 0761 Joining of Plastic Pipe – Butt Heat Fusion: Hydraulic Machine
Task 0771 Joining of Plastic Pipe – Sidewall Heat Fusion
106 Task 0781 Joining of Plastic Pipe – Electrofusion
Task 0791 Joining of Plastic Pipe – Socket Heat Fusion
107 Task 0801 Welding
Task 0811 Visual Inspection of Welding and Welds
108 Task 0821 Tubing & Fitting Installation – Instrument, Control and Sampling
Task 0831 Cast – Iron Caulked Bell and Spigot Joints – Installation and Maintenance of Mechanical Leak Clamp( s)
109 Task 0841 Cast Iron Joints – Sealing: Encapsulation
Task 0851 Internal Sealing – Cast Iron and Ductile Iron
110 Task 0861 Installation of Steel Pipe in a Ditch
Task 0871 Installation of Steel Pipe in a Bore
111 Task 0881 Installation of Steel Pipe Plowing/ Pull- In
Task 0891 Field Bending of Steel Pipe
112 Task 0901 Installation of Plastic Pipe in a Ditch
Task 0911 Installation of Plastic Pipe in a Bore
Task 0921 Installation of Plastic Pipe Plowing/ Pull- In
113 Task 0931 Installation of Plastic Pipe by Plowing/ Planting
Task 0941 Install Tracer Wire
114 Task 0951 Installation of Pipe Above Ground
Task 0961 Above Ground Supports and Anchors – Inspection, Preventive and Corrective Maintenance
115 Task 0971 Installation and Maintenance of Casing Spacers, Vents and Seals
Task 0981 Backfilling
116 Task 0991 Coating Application and Repair – Brushed or Rolled
Task 1001 Coating Application and Repair – Sprayed
Task 1011 External Coating Application and Repair – Wrapped
117 Task 1021 Apply or Repair Internal Coating Other Than by Brushing, Rolling or Spraying
Task 1031 Install or Repair Internal Liner
118 Task 1041 Install Mechanical Clamps and Sleeves – Bolted
Task 1051 Fit- Up of Weld Type Repair Sleeve
119 Task 1061 Install Composite Sleeves
Task 1071 Repair of Steel Pipe by Grinding
120 Task 1081 Tapping a Pipeline ( Tap Diameter 2 Inch and Less)
Task 1091 Tapping a Pipeline ( Tap Diameter Greater Than 2 Inch)
121 Task 1101 Tapping a Pipeline With a Built- In Cutter
Task 1111 Tapping Cast and Ductile Iron Pipe, and Low Pressure Steel Pipe
122 Task 1121 Bagging and Stopping Low Pressure Pipe
Task 1131 Stopper ( Stopple) Pipe
123 Task 1141 Squeeze Off Plastic Pipe
Task 1151 Squeeze Off Steel Pipe
124 Task 1161 Installation of Customer Meters and Regulators – Residential and Small Commercial
Task 1171 Installing Customer Meters – Large Commercial and Industrial
125 Task 1181 Installing and Maintaining Customer Pressure Regulating, Limiting, and Relief Device – Large Commercial & Industrial
126 Task 1191 Maintenance of Service Valves Upstream of Customer Meter
Task 1201 Temporary Isolation of Service Lines and Service Discontinuance
Task 1211 Odorization – Periodic Sampling
127 Task 1221 Odorization – Odorizer Inspection, Testing, Preventive and Corrective Maintenance
Task 1231 Inside Gas Leak Investigation
128 Task 1241 Outside Gas Leak Investigation
Task 1251 Hazardous Liquid Leak Investigation
129 Task 1261 Walking Gas Leakage Survey
Task 1271 Mobile Gas Leakage Survey – Flame Ionization
130 Task 1281 Mobile Gas Leakage Survey – Optical Methane
Task 1291 Locate Underground Pipelines
131 Task 1301 Install and Maintain Pipeline Markers
Task 1311 Inspect Pipeline Surface Conditions – Patrol Right of Way or Easement
Task 1321 Damage Prevention During Excavation Activities by or on Behalf of The Operator
132 Task 1331 Damage Prevention Inspection During Third Party Excavation or Encroachment Activities as Determined Necessary by Operator
Task 1341 Provide or Assure Adequate Pipeline Support During Operator Initiated Excavation Activities
133 Task 1351 Vault Inspection and Maintenance
Task 1361 Station Emergency Shutdown System – Inspection, Testing and Corrective Maintenance
134 Task 1371 Operate Gas Pipeline – System Control Center Operations
Task 1381 Operate Gas Pipeline – Local Facility Remote- Control Operations
135 Task 1391 Operate Liquids Pipeline – System Control Center Operations
136 Task 1401 Operate Liquids Pipeline – Local Facility Remote- Control Operations
Task 1411 Indirect Inspection Techniques
137 Task 1421 Direct Examination Techniques
Task 1431 Diving – Measure Structure to Electrolyte Potential
Task 1441 Diving – External Coating Application and Repair
138 Task 1451 Diving – Visual/ Tactile Inspection for Corrosion and Mechanical Damage – Buried or Submerged Pipeline
Task 1461 Diving – Measure and Describe Corrosion and Mechanical Damage – Buried or Submerged Pipeline
139 Task 1471 Diving – Install Galvanic Anodes on Submerged Pipelines
Task 1481 Diving – Locate Buried Underwater Pipelines
140 Task 1491 Diving – Movement of in- Service Underwater Pipeline
Task 1501 Diving – Install, Replace or Repair Support Structures on Existing Underwater Pipelines
141 Task 1511 Diving – Perform General Flange Assembly Procedures
Task 1521 Diving – Install Pipe End Connectors
142 Task 1531 Diving – Install Mechanical Clamps or Sleeves
Task 1541 Diving – Perform an Underwater Mechanical Tap
143 Task 1551 Diving – Stopper ( Stopple) Pipe
Task 1561 Diving – Valve – Inspection, Preventive and Corrective Maintenance
144 Task 1571 Diving – NDT – Magnetic Particle Testing
Task 1581 Diving – NDT – Manipulate Probe for Ultrasonic Testing
Task 1591 Diving – NDT – Radiographic Testing
145 Task 1601 Diving – Welding
Task 1611 Diving – Visual Inspection of Welding and Welds
146 Task 1621 Diving – Manually Operate Valves
148 NONMANDATORY APPENDIX 5B SUMMARY OF INTEGRATED TASK LIST Task 0001 Measure Structure- to- Electrolyte Potential
Task 0011 Conduct Close Interval Survey
Task 0021 Measure Soil Resistivity
Task 0031 Inspect and Monitor Galvanic Ground Beds/ Anodes
Task 0041 Installation and Maintenance of Mechanical Electrical Connections
Task 0051 Installation of Exothermic Electrical Connections
Task 0061 Inspect or Test Cathodic Protection Bonds
Task 0071 Inspect or Test Cathodic Protection Electrical Isolation Devices
Task 0081 Install Cathodic Protection Electrical Isolation Devices
Task 0091 Troubleshoot In- Service Cathodic Protection System
149 Task 0101 Inspect Rectifier and Obtain Readings
Task 0111 Maintain Rectifier
Task 0121 Collect Sample for Internal Corrosion Monitoring
Task 0131 Insert and Remove Coupons/ Probes for Internal Corrosion Monitoring
Task 0141 Visual Inspection for Atmospheric Corrosion
Task 0151 Visual Inspection of Buried Pipe and Components When Exposed
Task 0161 Visual Inspection for Internal Corrosion
Task 0171 Measure External Corrosion
Task 0181 Measure Internal Corrosion
Task 0191 Measure Atmospheric Corrosion
150 Task 0201 Visual Inspection of Installed Pipe and Components for Mechanical Damage
Task 0211 Measure and Characterize Mechanical Damage on Installed Pipe and Components
Task 0221 Inspect, Test and Maintain Sensing Devices
Task 0231 Inspect, Test and Maintain Programmable Logic Controllers
Task 0241 Inspect, Test and Maintain Liquid Leak Detection Flow Computers
Task 0251 Inspection and Testing, Corrective and Preventive Maintenance – Overfill Protection Systems
Task 0261 Inspection and Testing, Corrective and Preventive Maintenance – Tank Gauges for Leak Detection
151 Task 0271 Prove Flow Meters for Hazardous Liquid Leak Detection
Task 0281 Maintain Flow Meters for Hazardous Liquid Leak Detection
Task 0291 Inspect, Test and Maintain Gravitometers/ Densitometers for Hazardous Liquid Leak Detection
Task 0301 Manually Opening and Closing Valves
Task 0311 Adjust and Monitor Flow or Pressure – Manual Valve Operation
Task 0321 Valve Corrective Maintenance
152 Task 0331 Valve – Visual Inspection and Partial Operation
Task 0341 Valve – Preventive Maintenance
Task 0351 Pneumatic Actuator/ Operator Inspection and Testing, Preventive and Corrective Maintenance
Task 0361 Electric Actuator/ Operator Inspection and Testing, Preventive and Corrective Maintenance
Task 0371 Hydraulic Actuator/ Operator Inspection and Testing, Preventive and Corrective Maintenance
Task 0381 Spring Loaded Pressure Regulating Device – Inspection and Testing, Preventive and Corrective Maintenance
153 Task 0391 Pilot Operated Pressure Regulating Device – Inspection, Testing, Preventive and Corrective Maintenance
Task 0401 Controller Type Pressure Regulating Device – Inspection, Testing, Preventive and Corrective Maintenance
Task 0411 Spring Loaded Pressure Limiting and Relief Device – Inspection, Testing, Preventive and Corrective Maintenance
Task 0421 Pilot Operated Pressure Limiting and Relief Device – Inspection, Testing, Preventive and Corrective Maintenance
154 Task 0431 Pneumatic Loaded Pressure Limiting and Relief Device – Inspection, Testing, Preventive and Corrective Maintenance
Task 0441 Compressor Start- up and Shutdown – Manual
Task 0451 Pump – Start- up and Shutdown – Manual
Task 0461 Compressor Preventive Maintenance
Task 0471 Reciprocating Compressor Inspection, Testing and Corrective Maintenance
Task 0481 Centrifugal Compressor Inspection, Testing and Corrective Maintenance
Task 0491 Rotary Compressor Inspection, Testing and Corrective Maintenance
155 Task 0501 Pump Preventive Maintenance
Task 0511 Centrifugal Pump Inspection and Testing and Corrective Maintenance
Task 0521 Reciprocating Pump Inspection and Testing and Corrective Maintenance
Task 0531 Rotary Pump Inspection and Testing and Corrective Maintenance
Task 0541 Screw Pump Inspection and Testing and Corrective Maintenance
Task 0551 Explosive Atmosphere Detection and Alarm System Performance Test, and Corrective Maintenance
Task 0561 Pressure Test – Nonliquid Medium – MAOP Less Than 100 psi
Task 0571 Pressure Test – Nonliquid Medium – MAOP Greater Than or Equal To 100 psi
Task 0581 Pressure Test – Liquid Medium
156 Task 0591 Leak Test at Operating Pressure
Task 0601 NDT – Radiographic Testing
Task 0611 NDT – Liquid Penetrant Testing
Task 0621 NDT – Magnetic Particle Testing
Task 0631 NDT – Ultrasonic Testing
Task 0641 Visually Inspect Pipe and Components Prior to Installation
Task 0651 Routine Visual Inspection of Breakout Tanks
Task 0661 Inspection of Breakout Tanks
Task 0671 Joining of Plastic Pipe – Solvent Cement
Task 0681 Joining of Plastic Pipe – Stab Fittings
157 Task 0691 Joining of Pipe – Non- Bottom Out Compression Couplings
Task 0701 Joining of Pipe – Bottom Out Compression Couplings
Task 0711 Joining of Pipe – Compression Couplings
Task 0721 Joining of Pipe – Threaded Joints
Task 0731 Joining of Pipe – Flange Assembly
Task 0741 Joining of Pipe – Brazing or Soldering
Task 0751 Joining of Plastic Pipe – Butt Heat- Fusion: Manual
Task 0761 Joining of Plastic Pipe – Butt Heat- Fusion: Hydraulic Machine
Task 0771 Joining of Plastic Pipe – Sidewall Heat Fusion
Task 0781 Joining of Plastic Pipe – Electrofusion
158 Task 0791 Joining of Plastic Pipe – Socket Heat Fusion
Task 0801 Welding
Task 0811 Visual Inspection of Welding and Welds
Task 0821 Tubing & Fitting Installation – Instrument, Control and Sampling
Task 0831 Cast Iron – Caulked Bell and Spigot Joints – Installation and Maintenance of Mechanical Leak Clamp( s)
Task 0841 Cast Iron Joints – Sealing: Encapsulation
Task 0851 Internal Sealing – Cast Iron and Ductile Iron
Task 0861 Installation of Steel Pipe in a Ditch
Task 0871 Installation of Steel Pipe in a Bore
Task 0881 Installation of Steel Pipe Plowing/ Pull- in
159 Task 0891 Field Bending of Steel Pipe
Task 0901 Installation of Plastic Pipe in a Ditch
Task 0911 Installation of Plastic Pipe in a Bore
Task 0921 Installation of Plastic Pipe Plowing/ Pull- in
Task 0931 Installation of Plastic Pipe by Plowing/ Planting
Task 0941 Install Tracer Wire
Task 0951 Installation of Pipe Above Ground
Task 0961 Above Ground Supports and Anchors – Inspection, Preventive and Corrective Maintenance
Task 0971 Installation and Maintenance of Casing Spacers, Vents and Seals
160 Task 0981 Backfilling
Task 0991 Coating Application and Repair – Brushed or Rolled
Task 1001 Coating Application and Repair – Sprayed
Task 1011 External Coating Application and Repair – Wrapped
Task 1021 Apply or Repair Internal Coating other than by Brushing, Rolling or Spraying.
Task 1031 Install or Repair Internal Liner
Task 1041 Install Mechanical Clamps and Sleeves – Bolted
Task 1051 Fit- up of Weld Type Repair Sleeve
Task 1061 Install Composite Sleeves
Task 1071 Repair of Steel Pipe by Grinding
161 Task 1081 Tapping a Pipeline ( Tap Diameter 2 Inch and Less)
Task 1091 Tapping a Pipeline ( Tap Diameter greater than 2 Inch)
Task 1101 Tapping a Pipeline with a Built- in Cutter
Task 1111 Tapping Cast and Ductile Iron Pipe, and Low Pressure Steel Pipe
Task 1121 Bagging and Stopping Low Pressure Pipe
Task 1131 Stopper ( Stopple) Pipe
Task 1141 Squeeze off Plastic Pipe
Task 1151 Squeeze off Steel Pipe
162 Task 1161 Installation of Customer Meters and Regulators – Residential and Small Commercial
Task 1171 Installing Customer Meters – Large Commercial and Industrial
Task 1181 Installing and Maintaining Customer Pressure Regulating, Limiting, and Relief Device – Large Commercial & Industrial
Task 1191 Maintenance of Service Valves Upstream of Customer Meter
Task 1201 Temporary Isolation of Service Lines and Service Discontinuance
Task 1211 Odorization – Periodic Sampling
Task 1221 Odorization – Odorizer Inspection, Testing, Preventive and Corrective Maintenance
163 Task 1231 Inside Gas Leak Investigation
Task 1241 Outside Gas Leak Investigation
Task 1251 Hazardous Liquid Leak Investigation
Task 1261 Walking Gas Leakage Survey
Task 1271 Mobile Gas Leakage Survey – Flame Ionization
Task 1281 Mobile Gas Leakage Survey – Optical Methane
Task 1291 Locate Underground Pipelines
Task 1301 Install and Maintain Pipeline Markers
Task 1311 Inspect Pipeline Surface Conditions – Patrol Right of Way or Easement
164 Task 1321 Damage Prevention during Excavation Activities By or On Behalf of the Operator
Task 1331 Damage Prevention Inspection during Third Party Excavation or Encroachment Activities as Determined Necessary by Operator
Task 1341 Provide or Assure Adequate Pipeline Support During Operator Intiated Excavation Activities
Task 1351 Vault Inspection and Maintenance
Task 1361 Station Emergency Shutdown System – Inspection, Testing and Corrective Maintenance
Task 1371 Operate Gas Pipeline – System Control Center Operations
165 Task 1381 Operate Gas Pipeline – Local Facility Remote- Control Operations
Task 1391 Operate Liquids Pipeline – System Control Center Operations
Task 1401 Operate Liquids Pipeline – Local Facility Remote- Control Operations
Task 1411 Indirect Inspection Techniques
Task 1421 Direct Examination Techniques
Task 1431 Diving – Measure Structure to Electrolyte Potential
Task 1441 Diving – External Coating Application and Repair
Task 1451 Diving – Visual/ Tactile Inspection for Corrosion and Mechanical Damage – Buried or Submerged Pipeline
Task 1461 Diving – Measure and Describe Corrosion and Mechanical Damage – Buried or Submerged Pipeline
Task 1471 Diving – Install Galvanic Anodes on Submerged Pipelines
166 Task 1481 Diving – Locate Buried Underwater Pipelines
Task 1491 Diving – Movement of In- Service Underwater Pipeline
Task 1501 Diving – Install, Replace or Repair Support Structures on Existing Underwater Pipelines
Task 1511 Diving – Perform General Flange Assembly Procedures
Task 1521 Diving – Install Pipe End Connectors
Task 1531 Diving – Install Mechanical Clamps or Sleeves
Task 1541 Diving – Perform an Underwater Mechanical Tap
Task 1551 Diving – Stopper ( Stopple) Pipe
Task 1561 Diving – Valve – Inspection, Preventive and Corrective Maintenance
Task 1571 Diving – NDT – Magnetic Particle Testing
167 Task 1581 Diving – NDT – Manipulate Probe for Ultrasonic Testing
Task 1591 Diving – NDT – Radiographic Testing
Task 1601 Diving – Welding
Task 1611 Diving – Visual Inspection of Welding and Welds
Task 1621 Diving – Manually Operate Valves
168 NONMANDATORY APPENDIX 5C TASK LIST DEVELOPMENT PROCESS
170 NONMANDATORY APPENDIX 5D EXAMPLE OF EVALUATION CRITERIA
172 NONMANDATORY APPENDIX 6A ABNORMAL OPERATING CONDITIONS ( AOCS)
174 NONMANDATORY APPENDIX 8A EVALUATION METHOD SELECTION
8A-1 Introduction — The Reason for Setting an Appropriate Evaluation Method
8A-2 Definition And Examples of KSAs
175 8A-3 Appropriate Methods for KSAs
8A-3.1 Written evaluations
8A-3.2 Oral Interview evaluations
8A-3.3 Performance evaluations
176 8A-4 Consensus on Minimum Appropriate Evaluation Method
177 8A-5 Review of Final Product
178 NONMANDATORY APPENDIX 9A DIF ANALYSIS FOR SUBSEQUENT QUALIFICATION INTERVALS 9A- 1 Introduction
9A-2 The DIF Analysis Process
9A-3 SME Representation
9A-3.1 Consensus Group Representation
9A-3.2 Survey Sample Size
181 9A-4 DIF Rating Scales
9A-4.1 Difficulty
182 9A-4.2 Importance
183 9A-4.3 Frequency
9A-5 Specific Application of DIF Analysis to Determine Subsequent Qualification Intervals
184 9A-5.1 Use of the DIF Ratings and Decision Tree to Determine Subsequent Qualification Intervals
187 9A-5.2 Sample Decision Tree Application
188 NONMANDATORY APPENDIX 11A PROGRAM IMPLEMENTATION AND EFFECTIVENESS APPRAISALS
11A-1 Program Implementation Appraisal
189 11A- 2 Program Effectiveness Appraisal
ASME B31Q 2006