{"id":385092,"date":"2024-10-20T03:29:03","date_gmt":"2024-10-20T03:29:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-pas-62840-32021\/"},"modified":"2024-10-26T06:18:50","modified_gmt":"2024-10-26T06:18:50","slug":"bsi-pd-iec-pas-62840-32021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-pas-62840-32021\/","title":{"rendered":"BSI PD IEC PAS 62840-3:2021"},"content":{"rendered":"
This document applies to battery swap systems for removable RESS of electric road vehicle when connected to the supply network, with a rated supply voltage up to 480 V AC or up to 400 V DC, for battery systems with a rated voltage up to 120 V DC.<\/p>\n
\nNOTE 1 In the following countries, the acceptable nominal supply voltage is up to 600 V AC: CA, US.<\/p>\n<\/blockquote>\n
This document applies to battery swap systems for removable RESS\/EV where the removable RESS\/EV is stored for the purpose of transfer power between the battery swap station and removable RESS\/EV.<\/p>\n
Requirements for bidirectional energy transfer DC to AC are under consideration and are not part of this document.<\/p>\n
This document applies to:<\/p>\n
\n
- \n
battery swap systems supplied from on-site storage systems (for example buffer batteries etc);<\/p>\n<\/li>\n
- \n
manual, mechanically assisted and automatic systems;<\/p>\n<\/li>\n
- \n
battery swap systems intended to supply removable battery systems having communication allowing to identify the battery system characteristics;<\/p>\n<\/li>\n
- \n
battery swap systems intended to be installed at an altitude of up to 2 000 m.<\/p>\n<\/li>\n<\/ul>\n
The aspects covered in this document include:<\/p>\n
\n
- \n
requirements for power transfer between the battery systems;<\/p>\n<\/li>\n
- \n
additional requirements for communication;<\/p>\n<\/li>\n
- \n
the connection to supply network.<\/p>\n<\/li>\n<\/ul>\n
Additional requirements may apply to special locations.<\/p>\n
This document does not apply to:<\/p>\n
\n
- \n
safety requirements for mechanical equipment covered by ISO 10218 (all parts);<\/p>\n<\/li>\n
- \n
locking compartments systems providing AC socket-outlets for the use of manufacturer specific voltage converter units and manufacturer specific battery systems;<\/p>\n<\/li>\n
- \n
safety aspects related to maintenance;<\/p>\n<\/li>\n
- \n
electrical devices and components which are covered by their specific product standards;<\/p>\n<\/li>\n
- \n
trolley buses, rail vehicles;<\/p>\n<\/li>\n
- \n
any on-board equipment which is covered by ISO;<\/p>\n<\/li>\n
- \n
EMC requirements for on-board equipment while connected to the supply, which are covered by IEC 61851-21-1.<\/p>\n<\/li>\n<\/ul>\n
Requirements for battery swap systems using protective measures as covered by 410 of IEC 60364-4-41:2005 other than double or reinforced insulation are under consideration.<\/p>\n
PDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 4<\/td>\n CONTENTS <\/td>\n<\/tr>\n \n 6<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 8<\/td>\n INTRODUCTION <\/td>\n<\/tr>\n \n 9<\/td>\n 1 Scope <\/td>\n<\/tr>\n \n 10<\/td>\n 2 Normative references <\/td>\n<\/tr>\n \n 11<\/td>\n 3 Terms and definitions <\/td>\n<\/tr>\n \n 14<\/td>\n 4 Abbreviated terms
5 General requirements <\/td>\n<\/tr>\n\n 15<\/td>\n 6 Classification
7 Requirements for battery swap system
7.1 General <\/td>\n<\/tr>\n\n 16<\/td>\n 7.2 Battery swap station (BSS)
7.2.1 General
Figures
Figure 1 \u2013 Composition of the battery swap system
Tables
Table 1 \u2013 Sub-systems mandatory for use-cases <\/td>\n<\/tr>\n\n 17<\/td>\n 7.2.2 Lane systems
7.2.3 Handling system <\/td>\n<\/tr>\n\n 18<\/td>\n 7.2.4 Requirements for storage system <\/td>\n<\/tr>\n \n 20<\/td>\n 7.2.5 Charging system
7.2.6 Supervisory and control system
7.3 Supporting systems (optional)
7.4 Removable battery systems
7.4.1 General <\/td>\n<\/tr>\n\n 21<\/td>\n 7.4.2 Interoperability requirements
7.5 Power supply system (optional)
7.6 Interfaces
7.7 Zones of accessibility
Table 2 \u2013 Interoperability requirements <\/td>\n<\/tr>\n\n 22<\/td>\n 8 Communications
9 Protection against electric shock
10 Specific requirements for accessories
11 Cable assembly requirements
12 DRI EV supply equipment constructional requirements and tests
13 Overload and short-circuit protection
14 Emergency switching or disconnect (optional) <\/td>\n<\/tr>\n\n 23<\/td>\n 15 Marking and instructions
15.1 Installation manual <\/td>\n<\/tr>\n\n 24<\/td>\n Annex A (informative)Use cases
A.1 General
A.2 Use case description
A.2.1 Convenience store device (attended)
Table A.1 \u2013 UC convenience store device (attended) <\/td>\n<\/tr>\n\n 25<\/td>\n A.2.2 Unattended locking compartment <\/td>\n<\/tr>\n \n 26<\/td>\n Table A.2 \u2013 UC unattended locking compartment DC <\/td>\n<\/tr>\n \n 27<\/td>\n Table A.3 \u2013 UC unattended locking compartment AC <\/td>\n<\/tr>\n \n 28<\/td>\n A.2.3 Battery exchange box <\/td>\n<\/tr>\n \n 29<\/td>\n Table A.4 \u2013 UC battery exchange box <\/td>\n<\/tr>\n \n 30<\/td>\n A.2.4 Automatic battery exchange box <\/td>\n<\/tr>\n \n 31<\/td>\n A.2.5 Automatic vehicle storage system
Table A.5 \u2013 UC automatic battery exchange box <\/td>\n<\/tr>\n\n 32<\/td>\n Table A.6 \u2013 UC automatic vehicle storage system <\/td>\n<\/tr>\n \n 34<\/td>\n Annex B (informative)Examples of BSS wirings for removable battery systems
B.1 General
B.2 Example of a BSS wiring providing independent VCU for each battery system
Figure B.1 \u2013 Example of a removable battery system wiring (for information) <\/td>\n<\/tr>\n\n 35<\/td>\n Figure B.2 \u2013 Example of a BSS wiring providing independent VCU for each battery system <\/td>\n<\/tr>\n \n 36<\/td>\n B.3 Example of a BSS wiring providing common VCU for all battery systems
Figure B.3 \u2013 Example of a BSS wiring providing common VCU for all battery systems <\/td>\n<\/tr>\n\n 37<\/td>\n Annex C (informative)Examples of BSS for stackable removable battery systems
C.1 General
C.2 Connection of battery systems connected together
Figure C.1 \u2013 Example of a stackable removable battery system wiring <\/td>\n<\/tr>\n\n 38<\/td>\n Figure C.2 \u2013 Example of a BSS for stackable removable battery systems <\/td>\n<\/tr>\n \n 39<\/td>\n Figure C.3 \u2013 Connection of battery systems connected together <\/td>\n<\/tr>\n \n 40<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Electric vehicle battery swap system – Particular safety and interoperability requirements for battery swap systems operating with removable RESS\/battery systems<\/b><\/p>\n
\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2021<\/td>\n 44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":385097,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-385092","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/385092","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/385097"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=385092"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=385092"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=385092"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}