{"id":244384,"date":"2024-10-19T16:03:18","date_gmt":"2024-10-19T16:03:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60904-82014\/"},"modified":"2024-10-25T11:02:15","modified_gmt":"2024-10-25T11:02:15","slug":"bs-en-60904-82014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60904-82014\/","title":{"rendered":"BS EN 60904-8:2014"},"content":{"rendered":"
This International Standard specifies the requirements for the measurement of the spectral responsivity of both linear and non-linear photovoltaic devices. It is only applicable to single-junction devices. The spectral responsivity of a photovoltaic device is used in cell development and cell analysis, as it provides a measure of recombination and other processes occurring inside the semiconductor or cell material system.<\/p>\n
The spectral responsivity of a photovoltaic device is used for the correction of the spectral mismatch if a PV device is calibrated in a setup where the measurement spectrum is different from the reference spectral irradiance data given in IEC 60904\u20113<\/span> <\/span> and a reference device with a different spectral responsivity to the device under test is used. This procedure is given in IEC 60904\u20117<\/span> <\/span>.<\/p>\n Photovoltaic devices – Measurement of spectral responsivity of a photovoltaic (PV) device<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 6<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 8<\/td>\n 1 Scope
2 Normative references
3 Marking <\/td>\n<\/tr>\n\n 9<\/td>\n 4 Testing
4.1 General
4.2 Special considerations
4.3 Measurement under white bias light
4.4 Applying a bias voltage to the device under test
5 General description of spectral responsivity measurement <\/td>\n<\/tr>\n\n 11<\/td>\n 6 Apparatus
6.1 General <\/td>\n<\/tr>\n\n 12<\/td>\n Figures
Figure 1 \u2013 Example block diagram of a differential spectral responsivity measuring instrument using a continuous light source and a grating monochromator <\/td>\n<\/tr>\n\n 13<\/td>\n 6.2 Monochromatic light source
Figure 2 \u2013 Example block diagram of a differential spectral responsivity measuring instrument using a continuous light source and bandpass filters <\/td>\n<\/tr>\n\n 14<\/td>\n 6.3 PV device holder and temperature control
6.4 PV device contacts
6.5 Bias light
6.6 DC measurements <\/td>\n<\/tr>\n\n 15<\/td>\n 6.7 AC measurements in the presence of bias light
6.8 Reference device
7 Measurement of spectral responsivity using a constant light source
7.1 General method with a grating monochromator or filter wheel
7.2 Measurement of the reference device for setup calibration <\/td>\n<\/tr>\n\n 16<\/td>\n 7.3 Measurement of the device under test <\/td>\n<\/tr>\n \n 17<\/td>\n 7.4 Calculation of spectral responsivity <\/td>\n<\/tr>\n \n 18<\/td>\n 7.5 Simplifications
8 Measurement of spectral responsivity under pulsed light
8.1 Additional apparatus <\/td>\n<\/tr>\n\n 19<\/td>\n 8.2 Test procedure
9 Measurements of series-connected modules
9.1 General
9.2 Additional apparatus
9.3 Test procedure
Figure 3 \u2013 Example block diagram of a spectral responsivity measuring instrument using a pulsed light source and bandpass filters <\/td>\n<\/tr>\n\n 20<\/td>\n Figure 4 \u2013 Example of the measurement setup for the differential spectral responsivity measurement of a target cell in a PV module, where the supplemental bias light is applied on all the cells in the module other than the target cell <\/td>\n<\/tr>\n \n 21<\/td>\n Figure 5 \u2013 Example of the measurement setup for the differential spectral responsivity measurement of a target cell in a PV module, where the supplemental bias light is applied on all the cells in a string of the module other than the target cell
Figure 6 \u2013 Determination of the bias voltage Vb to set the voltage across the target cell to the short-circuit condition (see 9.3) <\/td>\n<\/tr>\n\n 22<\/td>\n 9.4 Calculation of spectral responsivity
10 Report <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2014<\/td>\n 26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":244388,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-244384","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/244384","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/244388"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=244384"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=244384"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=244384"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}