{"id":202610,"date":"2024-10-19T12:57:45","date_gmt":"2024-10-19T12:57:45","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/wa-residentialenergycode-2018\/"},"modified":"2024-10-25T05:35:22","modified_gmt":"2024-10-25T05:35:22","slug":"wa-residentialenergycode-2018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/wa\/wa-residentialenergycode-2018\/","title":{"rendered":"WA ResidentialEnergyCode 2018"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
3<\/td>\n | Table of Contents <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | 2018 WSEC_R Final.pdf CHAPTER 1 – Scope and Administration Section R101 – Scope and General Requirements Section R102 – Alternative Materials, Design and Methods of Construction and Equipment <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Section R103 – Construction Documents <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Section R104 – Inspections <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Section R105 – Validity Section R106 – Reference Standards Section R107 – Fees <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Section R108 – Stop Work Order Section R109 – Board of Appeals Section R110 – Violations Section R111 – Liability <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | CHAPTER 2 – Definitions Section R201 – General Section R202 – General Definitions <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | CHAPTER 3 – General Requirements Section R301 – Climate Zones TABLE R301.1: Climate Zones, Moisture Regimes and Warm-Humid Designations by State and County <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Section R302 – Design Conditions Section R303 – Materials, Systems and Equipment <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | TABLE R303.1.3(1): Default Glazed Window, Glass Door and Skylight U-Factor <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | TABLE R303.1.3(2): Default Opaque Door U-Factors TABLE R303.1.3(3): Default Glazed Fenestration SHGC and VT <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | TABLE R303.1.3(4): Default U-Factors for Skylights <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | TABLE R303.1.3(5): Small Business Compliance Table: Default U-Factors for Vertical Fenestration <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | CHAPTER 4 – Residential Energy Efficiency Section R401 – General Section R402 – Building Thermal Envelope <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | TABLE R402.1.1: Insulation and Fenestration Requirements by Component <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | TABLE R402.1.3: Equivalent U-Factors <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | EQUATION 1: Group R Occupancy Target UA <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | EQUATION 2: Group R Occupancy Proposed UA <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | TABLE R402.4.1.1: Air Barrier and Insulation Installation <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Section R403 – Systems <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | TABLE R403.6.1: Mechanical Ventilation System Fan Efficacy <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | Section R404 – Electrical Power and Lighting Systems Section R405 – Simulated Performance Alternative <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | TABLE R405.2: Mandatory Compliance Measures for Simulated Performance Alternative TABLE R405.3: Carbon Emissions Factors <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | TABLE R405.5.2(1): Specifications for the Standard Reference and Proposed Designs <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | TABLE R405.5.2(2): Default Distribution System Efficiencies for Proposed Designs <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | Section R406 – Additional Energy Efficiency Requirements TABLE R406.2: Fuel Normalization Credits <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | TABLE 406.3: Energy Credits <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | Section R407 – Certified Passive House <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | CHAPTER 5 – Existing Buildings Section R501 – General <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | Section R502 – Additions Section R503 – Alterations <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Section R504 – Repairs Section R505 – Change of Occupancy or Use <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | CHAPTER 6 – Referenced Standards <\/td>\n<\/tr>\n | ||||||
64<\/td>\n | APPENDIX A – Default Heat Loss Coefficients Section A101 – General Requirements <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | Section A102 – Ceilings <\/td>\n<\/tr>\n | ||||||
73<\/td>\n | Section A103 – Above Grade Walls <\/td>\n<\/tr>\n | ||||||
89<\/td>\n | Section A104 – Below Grade Walls and Slabs <\/td>\n<\/tr>\n | ||||||
91<\/td>\n | Section A105 – Floors Over Unconditioned Space <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | Section A106 – On Grade Slab Floors <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | Section A107 – Default U-Factors for Doors <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | Section A108 – Air Infiltration <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | APPENDIX RA \/ RB – Optional Energy Efficiency Measures <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | APPENDIX C – Exterior Design Conditions <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Washington State Energy Code, Residential, 1st Printing – Effective July 1, 2020<\/b><\/p>\n |