Fine ceramics (advanced ceramics, advanced technical ceramics). Measurement method of piezoelectric strain at high electric field
Published By | Publication Date | Number of Pages |
BSI | 2015 | 18 |
This International Standard specifies the measurement method of piezoelectric strain at high electric field for high power piezoelectric devices. This International Standard is intended to be used to determine the piezoelectric strain coefficient of the materials by measuring strain vs. electric field:
-
applied electric field: 0 to 2 MV/m;
-
frequency of electric field: 0,1 to 1 Hz.
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | Foreword |
7 | 1 Scope 2 Normative references 3 Terms and definitions, and symbols 3.1 Terms and definitions |
8 | 3.2 Symbols 4 Measuring environment 5 Specimens 5.1 General |
9 | 5.2 Shape and size 5.3 Electrodes 5.4 Polarization 6 Principle 7 Measurement equipment 7.1 Equipment |
10 | 7.2 Components of equipment |
11 | 7.3 Environment of specimen holder 7.4 Calibration of measurement equipment 8 Measurement conditions 9 Measurement procedures |
12 | 10 Calculations and results 11 Test report |
14 | Annex A (informative) Example of reference sample |