BS EN 12616:2022:2023 Edition

$102.76

Surfaces for sports areas. Test methods for the determination of vertical water infiltration and horizontal water flow rates

Published By Publication Date Number of Pages
BSI 2023 22
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document has two parts. Part 1 specifies four methods for the determination of the vertical water infiltration rate of different types of sports surfacing. Method A is suitable for measuring the vertical water infiltration rate of synthetic, textile and synthetic turf sports surfaces in the laboratory. Method B is suitable for on-site measurements of the Vertical Water Infiltration Rate of synthetic, textile, synthetic turf and bound mineral sports surfaces. Method C is suitable for on-site measurements of the vertical water infiltration rate of natural turf sports surfaces. Method D is suitable for measuring the for on-site measurements of the vertical water infiltration rate of unbound mineral sports surfaces. NOTE For filled synthetic turf and unbound mineral surfaces, laboratory tests are considered to give a more precise indication of how a surface will perform. Part 2 specifies a method for determining the horizontal water flow rate of synthetic, textile and synthetic turf surfaces in the laboratory.

PDF Catalog

PDF Pages PDF Title
2 undefined
6 1 Scope
2 Normative references
3 Terms and definitions
4 Part 1 – Determination of vertical water infiltration rate
4.1 Method A – laboratory determination of synthetic turf, textile and synthetic sports surfaces
4.1.1 Principle
4.1.2 Apparatus
7 4.1.3 Test specimen
8 4.1.4 Conditioning
4.1.5 Procedure
4.1.6 Calculation and expression of results
4.1.7 Test report
9 4.2 Method B – on-site determination on synthetic textile, synthetic turf, and bound mineral sports surfaces
4.2.1 Principle
4.2.2 Apparatus
10 4.2.3 Test conditions
11 4.2.4 Number and distribution of test locations on site
4.2.5 Procedure
4.2.6 Calculation and expression of results
12 4.2.7 Test report
4.3 Method C – on-site determination on Natural turf
4.3.1 Apparatus
4.3.2 Number and distribution of test locations
4.3.3 Procedure
13 4.3.4 Calculation and expression of results
4.3.5 Test report
4.4 Method D – on-site determination unbound mineral surfaces
4.4.1 Apparatus
4.4.2 Number and distribution of test locations
14 4.4.3 Procedure
4.4.4 Calculation and expression of results
4.4.5 Test report
15 5 Part 2 – Determination in the laboratory of horizontal water flow rate
5.1 Principle
5.2 Apparatus
17 5.3 Test specimens
5.4 Conditioning
5.5 Procedure
5.5.1 Method
18 5.5.2 Acquisition of values
5.5.3 Test directions
5.5.3.1 Samples with single water flow direction
5.5.3.2 Sample with water direction in both senses (at 90°)
5.6 Calculation and expression of results
19 5.7 Test report
20 Annex A (Informative)Sample preparation for the determination in the laboratory of horizontal water flow rate
BS EN 12616:2022