C946-91(1996)e1 Standard Practice for Construction of Dry-Stacked, Surface-Bonded Walls

Published By Publication Date Number of Pages
ASTM 1996 3
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

ASTM C946-91-e1-Reapproved1996

Historical Standard: Standard Practice for Construction of Dry-Stacked, Surface-Bonded Walls

ASTM C946

Scope

1.1 This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. It does not include grout, reinforcing, anchorage, or control joints since their use is essentially the same as conventional concrete masonry construction, unless specifically mentioned in this practice.

Note 1—Design and construction procedures for conventional concrete masonry construction have been written by the American Concrete Institute, “Building Code Requirements for Concrete Masonry Structures” and the National Concrete Masonry Associations, “Specification for the Design and Construction of Load-Bearing Concrete Masonry.”

1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

dry stacked; fiber reinforced; mortar; packaged; surface bonding